background image

 

5

 

User’s operating instructions  

 

Domestic hot water temperature control

 

 

Through  this  knob  it  is  possible  to  allow  the  preparation  of  the  storage  tank  and  to  adjust  the 
temperature of the domestic hot water:  

 

 

With  the  pointer  of  the  knob  positioned  in  the  range  shown  beside  it  is  possible  to  adjust  the 
temperature of the domestic hot water. The adjustment range is between a minimum of 25°C and 
a maximum of 60°C. 

 

If the rotating switch is in the position 

, the D.H.W. circuit is not in operation (in this case no warm water is available).  

If,  in  the  mean  time,  the  rotating  switch  (A)  is  in  the  position  (B) 

,  the  antifreeze  function  of  the  storage  tank  is 

activated.  

 

 

F button  

 
ATTENTION! 
Function not active for boilers with domestic hot water production by storage tank. 

 

 

 

Power On indicator led 

 

 

This led will illuminate when the boiler is connected to the electricity supply  

 

Central heating mode indicator led 

 

 

This  led  will  illuminate  when  there  is  a  request  for  central  heating.  If  simultaneously  there  is  a  request  for 
domestic hot water production, the led will switch off. 

 

Burner On indicator led 

 

 

When this led is illuminated it indicates that the burner is functioning correctly, both in central heating request 
mode and in domestic hot water production mode. 

 

Lock-out indicator led  

 

When this led is illuminated it indicates that the burner’s safety cut-off device has shut-down the boiler.  

 

Reset key  

 

The function of this key is to reset correct boiler operation after the cut-off device has shutdown the boiler (red 

 led indicator illuminated)  

If the cut-off device operates more than 3 times, causing boiler shutdown, do not try to reset the boiler 
yourself. Contact your nearest VIADRUS authorized After Sales Service Centre.
 

 

 

Summary of Contents for ViaKON 24 B

Page 1: ...17 2013 ...

Page 2: ...pliance or other objects The appliance is designed to be used in pumped hot water central heating systems and for domestic hot water production Any other use of this appliance will be considered improper VIADRUS declines any responsibility for any damages or injuries caused by an improper use in this case the risk is completely at the user s responsibility In order to use the appliance according t...

Page 3: ...s animals or damage to property The manufacturer shall not be held liable for any such injury and or damage 5 SAFETY WARNINGS WARNING The installation adjustment and servicing of this appliance must be carried out by a competent person and installed in accordance with the current standards and regulations Failure to correctly install this appliance could cause injury to persons animals or damage t...

Page 4: ...ressure gauge Summer winter selector Central heating temperature control knob By turning this knob it is possible to choose the following operating modes Summer only DHW production Winter DHW production and central heating temperature control When the switch is in the Summer position the central heating mode is excluded However the frost protection mode remains enabled With the knob in the positio...

Page 5: ...nk Power On indicator led This led will illuminate when the boiler is connected to the electricity supply Central heating mode indicator led This led will illuminate when there is a request for central heating If simultaneously there is a request for domestic hot water production the led will switch off Burner On indicator led When this led is illuminated it indicates that the burner is functionin...

Page 6: ...per scale the central heating hot water flow temperature is indicated On the lower scale the water pressure in the central heating system is indicated If the pressure is lower then 0 7 bar then it will be necessary to restore the correct pressure by operating the filling valve when the system is cold and the boiler not operating 6 2 CHECK LIST BEFORE COMMISSIONING THE BOILER Before commissioning t...

Page 7: ...inter in position 1 corresponds to the minimum temperature of 35 C the knob pointer in position 1 corresponds to the maximum temperature of 80 C SWITCH OFF OF THE BOILER Deactivation of heating mode By rotating the knob B completely to the left the heating is deactivated but the D H W mode remains active Summer mode Complete boiler shut down If the boiler is completely shut down the CH and DHW mod...

Page 8: ... metal systems Do not use anti frost products for motor vehicles because they could seriously damage the water gaskets If for any reason there is no gas or electrical supply the above described frost protection mode will not be active 6 5 ELIMINATING THE FAULTS If the boiler goes into lock out the user can reset the boiler only in the following cases Lock out led illuminated and flashing Cause Ins...

Page 9: ...ck is in the On position and that the air present in the piping has been vented Press the reset key to restore correct boiler operation If the cut off device operates repeatedly a maximum of 3 times causing boiler shutdown do not try to relight the boiler your self Contact your nearest VIADRUS authorized After Sales Service Centre WARNING If the boiler goes into lock out and or the leds continue t...

Page 10: ...ng factory The manufacturer requires for the guarantee applicability In the meaning of the Act No 222 94 Coll On conditions for business activities and government administration execution in certified branches and on Government Energy Inspection and ČSN 38 6405 amendment 1 5 99 EN 1775 to perform periodically 1 x year a gas boiler inspection Inspections may only be performed by an authorized organ...

Page 11: ...kaging unit EN 13429 NO 3 1 Recovery by material recycling ensure recyclability in all terms of the standard for the functional packaging unit EN 13430 YES 3 2 Recovery in the form of energy ensure that calorific gain is achievable for the functional packaging unit EN 13431 YES Iron NO 3 3 Recovery by composting ensure compost ability in all terms of the standard for the functional packaging unit ...

Page 12: ...ors of transcript or press Also reserves the right to bring those changes that will hold necessary to it own products or profits without jeopardizing its essential characteristics VIADRUS a s Bezručova 300 735 81 Bohumín Tel 420 596 083 050 Fax 420 596 082 822 www viadrus cz info viadrus cz ...

Reviews: