| BL530 PH/RX DOSAGE SYSTEM
List of Configuration Parameters
In this section are listed all the configuration parameters. It is recommended
to fill the last column with the values set for your application.
PAR
Description
Min. Value
Max. Value
Default
Value
Set
Value
P01
Functioning Type Pump 1
ON-OFF /
Proportional
ON-OFF
P02
Setpoint Pump 1
0,00pH
14,00pH
7,00pH
P03
Hysteresis Pump 1
0,20pH
2,00pH
0,50pH
P04
Dosage Pump 1
Acidification /
Alkalinisation
Acidification
P05
Time Base Pump 1
if P01= ON-OFF
if P01= Proportional
5%
30 sec.
100%
360 sec.
60%
60 sec.
P06
Functioning Type Pump 2
ON-OFF /
Proportional
ON-OFF
P07
Setpoint Pump 2
0mV
1000mV
750mV
P08
Hysteresis Pump 2
20mV
200mV
50mV
P09
Dosage Pump 2
Chlorination /
De-
chlorination
Chlorination
P10
Time Base Pump 2
if P06= ON-OFF
if P06= Proportional
5%
30 sec.
100%
360 sec.
60%
60 sec.
P11
Alarm Pump 1
0 min.
240 min.
0 min.
P12
Alarm Pump 2
0 min.
240 min.
0 min.
P13
Start Delay
0 min.
60 min.
0 min.
P14
Language
Model
Italian,
French,
Model
Italian,
French,
BL530-1:
Dutch,
German
BL530-2:
English,
Spanish
Dutch
English
P15
Restore default values
0
255
0
P16
Password
0
255
0
P17
Alarm Functioning
Relay NO /
Relay NC
Relay NO
P18
Flow Functioning
Input NO /
Input NC
Input NO
P19
pH Equilibrium
0 min.
240 min.
0 min.