5
UV-C and Pool equipment
TECHNICAL SPECIFICATIONS
pH/RX Inputs
Available on BNC connectors, input impedance > 10^12 Ω.
Measure Ranges
0.00 to 14.00 pH, 0 to 1000 mV (redox).
Precision
Deviations less than 1% of the full scale
(when properly calibrated).
Precision Repeatability
Better than 0.2% of the full scale.
Configuration
Two configuration level (standard and advanced).
LEV Inputs
2 independent inputs for level sensors, available
on connectors, SPDT contact 5 V / 5 mA.
FLOW Input
1 input that can be used for connecting both the filter pump
contactor or the flow sensor (SPDT contact 5 V / 5 mA).
Serial Port
RS232, available on external connector (optional).
Relay Output
NO/NC configurable contact for alerting (optional).
Display
Large alphanumeric, double row (x 16 characters) LCD, with backlight
Dosing Pumps
Flow rate: 4 l/h @ 1 bar.
Materials: fiberglass reinforced PP pump head and fittings,
Santoprene (silicone upon request internal tube, PBT roller holder,
Delrin (self- lubricant) rollers. Max suction height: 1.5 m.
Power Supply
Standard 230 V~, 50 Hz (other options upon request) ; 20W.
Protection Fuse
F1A 5x20 (230V ~).
Environment
Storage temperature -20 tot +60° C.
Working temperature -10 tot +40° C.
RH
max. 90% non condensing.
Casing
Self-extinguish plastic material with polyester front panel.
Installation
Wall installation with supplied screws and stoppers.
Protection Rate
IP65.
Dimensions
290 x 280 x 175 mm.
Weight
Approx. 4 kg.
180
250
280
29
0
27
2
17
3
Ø6.
5