![Vexar CD32M-B Owner'S Manual Download Page 9](http://html1.mh-extra.com/html/vexar/cd32m-b/cd32m-b_owners-manual_1010622009.webp)
www.desatech.com
119212-01B
9
Vertical (V) Horizontal (H) Series
.29
3
/
4
".min..
17".max..
CD32
.32
3
/
4
".min..
17".max..
CD36
.36
3
/
4
".min..
17".max..
CD42
Horizontal.High.
Wind.Square
Termination
Wall.
Firestop
45°.Elbow
Adjustable.Pipe.
12".Max.
Square Termination
inStALLAtiOn
Continued
Figure 9 - Horizontal Termination
Configuration for Square and Round
Terminations
45°.Elbow
Wall.
Firestop
Round.
Termination.
Cap
Exterior.Portion.of.
Wall.Firestop.(Round.
Termination.Only)
Round Termination
Slide.Ring.
Over.Elbow.
to.Complete.
Connection
CD32
.Series
V
ertical
.(V)
Minimum
CD36
.Series
V
ertical
.(V)
Minimum
CD42
.Series
V
ertical
.(V)
Minimum
Required
V
ertical
.Pipe
Horizontal
.(H)
Maximum
*
40
1
/
2
"
*
43
1
/
2
"
*
46
1
/
4
"
None 30"
51
1
/
2
"
54
1
/
2
".
57
1
/
4
"
1.ft.
48"
63
1
/
2
"
66
1
/
2
"
69
1
/
4
"
2.ft.
60"
75
1
/
2
"
78
1
/
2
"
81
1
/
4
"
3.ft.
84"
87
1
/
2
"
90
1
/
2
"
93
1
/
4
"
4.ft.
20'
Figure 10 - Horizontal Termination
Configuration for Corner Installation
Using One 90° Elbow
Square.
Termination
Wall.
Firestop
Not.to.Exceed.
(H).Limits
As.Required.
for.(V)
See.Chart.
for.Pipe.
Section.
Required
45°.
Elbow
90°.Elbow
90°.Elbow
Square.
Termination.
Wall.
Firestop
45°.Elbow
12".
Minimum
*
Note:.Ground.Floor.Corner.Venting.
Not.to.Exceed.
(H).Limits