SeLecting LOcAtiOn
Continued
•. Never.obstruct.the.openings.of.the.appli-
ance or flow of ventilation air. Keep the
control.compartments.accessible.
•. Do. not. locate. appliance. close. to. where.
gasoline or other flammable liquids may be
stored..The.appliance.must.be.kept.clear.
and.free.from.combustible.materials.
•. Do.not.use.this.appliance.if.any.part.has.
been.under.water..Immediately.contact.a.
local. service. technician. to. examine. the.
appliance.and.to.replace.any.part(s).of.the.
control. ignition. system. and. other. related.
components. that. have. been. submerged.
under.water.
Pre-inStALLAtiOn
PrePArAtiOn
CAUTION: Do not block
required air spaces with insula
-
tion or any other material. Do not
obstruct the effective opening
of the appliance with any type
of facing material.
CLEARANCES TO COMBUSTIBLES
Minimum.clearances.to.combustibles.for.the.
fireplace are:
•. Back.and.Sides.of.Fireplace.. . . . . . . . 0"
•. Floor .. . . . . . . . . . . . . . . . . . . . . . . . . . 0"
•. Perpendicular.Wall .. . . . . . . . . . . . . . . 6"
•. Front .. . . . . . . . . . . . . . . . . . . . . . . . . 36"
•. Top.of.Standoffs.. . . . . . . . . . . . . . . . . . 0"
MANTEL CLEARANCES
Woodwork,. such. as. wood. trims,. mantles.
and. other. combustible. materials. should. be.
placed. within. the. required. clearance. speci-
fied in Figure 2.
Figure 2 - Mantel Clearances
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
Mantel
Depth
Mantel From Top
of Opening
(1).14"
(A).16"
(2).12"
(B).14"
(3).10"
(C).12"
(4).8"
(D).10"
(5).6"
(E).8"
(6).4"
(F).6"
(7).2"
(G).4"