INSTALLATION FOR VERTICAL
TERMINATION
Note
: Vertical restrictor must be installed
in all vertical installations.
1.. Determine.the.route.your.vertical.venting.
will.take..If.ceiling.joists,.roof.rafters,.or.
other. framing. will. obstruct. the. venting.
system,.consider.an.offset.(see.Figure.19).
to. avoid. cutting. load. bearing. members..
Note:
.Pay.special.attention.to.these.instal-
lation.instructions.for.required.clearances.
(air.space).to.combustibles.when.passing.
through.ceilings,.walls,.roofs,.enclosures,.
attic.rafters,.etc..Do.not.pack.air.spaces.
with.insulation..Also.note.maximum.verti-
cal. rise. of. the. venting. system. and. any.
maximum.horizontal.offset.limitations.
2. Set the fireplace in desired location. Drop
a.plumb.line.down.from.the.ceiling.to.the.
position of the fireplace exit flue. Mark the
center.point.where.the.vent.will.penetrate.
the.ceiling..Drill.a.small.locating.hole.at.
this.point.
.
Drop.a.plumb.line.from.the.inside.of.the.
roof. to. the. locating. hole. in. the. ceiling..
Mark.the.center.point.where.the.vent.will.
penetrate.the.roof..Drill.a.small.locating.
hole.at.this.point.
Figure 13 - Offset with Wall Strap and 45°
Elbows
45°.Elbow
Wall.Strap
Roof.
Flashing
Ceiling.Firestop
inStALLAtiOn
Continued
Vertical Termination Configurations
Figures. 14. through. 17. show. four. different.
configurations for vertical termination.
Vertical.(V)
Horizontal.(H
1
).+.
Horizontal.(H
2
)
5'.min.
2'.max.
6'.min.
4'.max.
7'.min.
6'.max.
8'.min.
8'.max.
20'.max.
8'.max.
Figure 14 - Vertical Venting
Configuration Using Two 90° Elbows
with Two Horizontal Runs (Vertical
Round High Wind Termination Shown)
Note:
Install.
restrictor.into.
inner.collar.of.
fireplace as
shown.
45°.Elbow
Venting with Two 90° Elbows