inStALLAtiOn
Continued
Figure 19 - Remote Control Receiver
Remote.
Control.
Receiver
Convertible.
Gas.Valve
GAS SUPPLY TESTING
NOTICE: This section is in-
tended as a guide for qualified
technicians installing gas to the
appliance.
WARNING: Do not connect
appliance before pressure test
-
ing gas piping. Damage to gas
valve may result and an unsafe
condition may be created.
The.appliance.and.its.individual.shutoff.valve.
must. be. disconnected. from. the. gas. supply.
piping.system.during.any.pressure.testing.of.
that.system.at.test.pressures.in.excess.of.1/2.
psig.(3.5.kPa)..
The.appliance.must.be.isolated.from.the.gas.
supply.piping.system.by.closing.its.individual.
shutoff.valve.during.any.pressure.testing.of.
the.gas.supply.piping.system.at.test.pressures.
equal.to.or.less.than.1/2.psig.(3.5.kPa).
The.gas.control.valve.is.secured.underneath.
the firebox. Two 1/8" ports are provided on
the.gas.control.valve.for.pressure.test.gauge.
connections.(see.Figure.20).
Figure 20 - Gas Control Valve
ON/OFF.
Knob
Pilot.Adjustment
Inlet.
Pressure Outlet.
Pressure
Flame.
Adjustment Knob
Pilot.Gas.Line.
Do Not Kink
To.Pilot.
Burner
To.Main
Burner
GAS LINE HOOK-UP
WARNING: Gas line hook-
up should be done by your gas
supplier or a qualified service
person.
WARNING: Before you pro
-
ceed, make sure your gas supply
is OFF.
An.equipment.shutoff.valve.has.been.included.
in the fireplace's gas supply system. Consider
installing.an.extra.shutoff.valve.outside.the.ap-
pliance’s.enclosure.(check.local.codes),.where.
it.can.be.accessed.more.conveniently.with.a.
key.through.a.wall.as.shown.in.Figure.21.
In.conformance.with.local.codes,.route.a.1/2".
NPT.gas.line.towards.the.appliance.coming.in.
from.either.the.bottom,.left.or.right.side.of.the.
fireplace (see Figure 22, page 14).
Figure 21- Typical Exterior Wall Gas
Shutoff Installation
Key
Extension
Shutoff.
Valve
The.remote.control.receiver.is.factory.wired.
and.connected.to.the.convertible.gas.valve.
as.shown.in.Figure.19.