03. OPERATION OF THE MACHINE
01.01.
INSERTING THE NEEDLE (2- NEEDLE)
-2-2
CAUTION! RISK OF INJURY!
Push the X-button at the machine head, the red light illuminates showing the active
“BLOCKED MODE“
, or turn the machine off before inserting the needles. Failure to
comply produces a risk of injury in case of an unintentional machine operation.
INFO
Only use needles from the system intended for the machine.
(Needle system 134-35)
01. Push the X-button at the machine head, the red light illuminates showing
the active
“BLOCKED MODE”
, or turn the machine off.
02. Loosen the screws
1
.
03. Push the needles
2
fully in until they stop. Make sure that the groove
3
of the right needle points to the right and the left needle to the left.
04. Tighten the screws
1
again.
05. Push the X-button or switch the machine on again and follow the instructions
displayed on the control panel.
NOTE:
Before activating the machine by the X-button make sure to remove
sewing material
or
other items
below the sewing feet if necessary and
follow the instructions displayed on the control panel.