In the 

“Send/Receive” 

section, you can monitor the communication between PC and 

IF SMI RS-485 module. You will see the Transmit and Receive data stream.

7.5  Send / Receive

On the 

“Motor ID” 

tab-sheet, you will find the “Motor ID” based com-

mands. The motor you want to address, can be selected with the spin edit 

box (in the dark gray part, behind Motor ID). Motor ID can be set from “0” to 

“15”. Next, press a command button, like “GET_SERIAL”, “GET_PARAM”, 

“SET_SMI_ID”, “GET_POS1”, “SET_POS1”, “GET_POS2”, “SET_POS2” 

or “GETDETSTAT”.

REMARK: 

  Some commands need additional parameters. See section 

“6. Protocol”

 for detailed information.

7.4  Motor ID based commands

On the 

“Motor Mask”

 tab-sheet, you will find the “motor mask” based 

commands. With the checkboxes 15 to 0 you can select which motor(s) 

you want to address, or simply select “All”, to address all motors. Next, 

press a command button, like “UP”, “DOWN”, “STOP”, “STEP_UP”, 

“STEP_DOWN”, “SET_POS”, “SET_TILT”, “SET_POS_STEP_UP”, 

 

“SET_POS_STEP_DOWN”, “GOTO_POS1” or “GOTO_POS2”.

REMARK: 

  Some commands need additional parameters. See section 

“6. Protocol”

 for detailed information.

7.3 Motor Mask based commands

Summary of Contents for IF SMI RS-485 230 VAC-DIN

Page 1: ...hould spread high value solutions and promote drives and controls on the market The applications in roller shutters and sun protection systems require extreme robustness and economic efficiency SMI ha...

Page 2: ...Long press Modify current base address Double press Show error log UP DOWN button In main menu Steer all attached SMI motors UP DOWN In address menu Increase Decrease base address Error log menu Show...

Page 3: ...n twice within 1 second The text Er is briefly visible to indicate that the error log is shown Next the last occurred error is shown blinking By pressing the UP button the previous occurred error will...

Page 4: ...3 1 MSG_UP This message is used to move all or a set of sun blind to the top position Message SID LEN CMND MSK0 MSK1 CRC16 MSK0 LSB of 16 bit mask to select motor address 0 7 MSK1 MSB of 16 bit mask t...

Page 5: ...0 Manufacturer ID See SMI Group website for actual list Bit7 4 Motor type An indication from 0 to 15 which each SMI motor manufacturer can freely use to identify their SMI motor type REMARK An Manufac...

Page 6: ...G_ERROR Request gateway options Message SID LEN CMND CRC16 Response SID LEN CMND OPTIONS CRC16 OPTIONS Stored gateway options See gateway options layout as described above Default gateway options 0x00...

Page 7: ...of 16 bit intermediate position 2 POS1 MSB of 16 bit intermediate position 2 6 4 1 MSG_VERSION This message is used to check to version number of the application Message SID LEN CMND CRC16 Response SI...

Page 8: ...lt information uses a manufacturer specific SMI command which is currently only supported by Vestamatic SMI motors For non Vestamatic SMI motors TILT value 0x00 is returned CYCLE0 3 32 bits cycle coun...

Page 9: ...n be set from 0 to 15 Next press a command button like GET_SERIAL GET_PARAM SET_SMI_ID GET_POS1 SET_POS1 GET_POS2 SET_POS2 or GETDETSTAT REMARK Some commands need additional parameters See section 6 P...

Page 10: ...GmbH Art Nr 3060 001 GB 4518 A06 Vestamatic GmbH Dohrweg 27 D 41066 M nchengladbach www vestamatic com 10 10 G IF SMI RS 485 DIN 8 1 Wiring diagram IF SMI RS 485 24VDC DIN 8 2 Wiring diagram IF SMI R...

Reviews: