Installation Manual
Installation Checklist
After the water heater installation, examine the following checklist. If you are not able to answer "Yes" to all of the items in the checklist, review
the appropriate sections. To troubleshoot any operational problems, refer to "Troubleshooting" in the User's Manual.
If there are additional questions or if you need assistance, contact technical support at 1-800-761-0053.
Location
Check
Is the make-up air supply free from corrosive elements and flammable vapors?
Is the water heater clear of combustible materials?
Is the gas control valve accessible for servicing?
Have you maintained the proper service and maintenance clearances?
Gas connection
Check
Have you tested all the fittings for leaks?
Does the gas supply match the gas type specified on the water heater's rating plate?
Is the gas supply pressure adequate as the gas supply pressure specified in the water heater's rating plate?
Does the installation conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54?
Does the gas line have an inner diameter of at least 1/2"?
Water connection
Check
Is the water supply pressure sufficient (greater than 40 PSI)?
Have you verified that the cold water line and the hot water line do not intersect and have you tested for leaks?
Is the approved pressure relief valve installed properly?
Have you verified that there are no products installed which exceeds the maximum pressure specified in the water heater's
rating plate?