![Vesta MZ-1 Installation Manual Download Page 85](http://html.mh-extra.com/html/vesta/mz-1/mz-1_installation-manual_1008986085.webp)
82
15.2. Event Code
The events are reported with a qualifier before the event code. The qualifier “
1
” means the event
has taken place, “
3
” means the event has been restored. For example, if the Control Panel
reports “1302”, it means the panel is under low battery; if the Control Panel reports “3302”. It
means the panel low battery condition has been restored.
100 – Medical
101 – Personal emergency
When the Wrist Transmitter / Emergency Pendant (WTR) is pressed.
102 – Inactive
110 – Fire
111 – Smoke
When the Smoke Detector (SD) is triggered.
114 – Heat
When the Heat Detector (HD) is triggered.
120 – Panic
When a device set to Personal Attack is triggered
121 – Duress
When the Duress Code is entered to disarm or arm the system.
122 – Silent Panic
When the panic button on a Remote Controller (RC) set to silent panic is pressed.
When a device set to Silent Panic is triggered
130 – Burglar
When an Instant Burglar Alarm is triggered
When an Instant Silent Burglar Alarm is triggered
131 – Burglar Perimeter
When Entry Time is triggered under Away Arm mode and the timer expires without
disarming the system.
When a Delay Burglar Alarm device is triggered during Away Entry Time and the timer
expires without disarming the system.
132 – Burglar Interior
When Entry Time is triggered under Home Arm mode and the timer expires without
disarming the system.
When a Delay Burglar Alarm device is triggered during Home Entry Time and the timer
expires without disarming the system.
133 – 24 Hours
When a device set as
24 Hour
is triggered.
136 – Burglar Outdoor
When a Burglar Outdoor Alarm is triggered.
137 – Panel Tamper
When the Control Panel tamper switch is triggered.