5.4. Area
This page is for you to configure area settings.
Final Door
Final Door On:
When the system is Away Armed with a Door Contact set to
Entry
attribute, the system will automatically arm the system once the Door Contact is closed
even if the entry delay timer has not expired yet.
Final Door Off:
When the system is Away Armed with a Door Contact set to
Entry
attribute, the system will only arm the system after the entry delay timer expires.
Factory Default is set to
Final Door Off
.
Arm Fault Type
Confirm:
When set to
Confirm
, If you attempt to arm when a fault exists within the
system, the arming action will be prohibited, and a message will be displayed “Fault
exists! Please Confirm!” You need to arm the system again to confirm your action and
arm the system. (Factory Default)
Direct Arm:
When set to
Direct Arm
, If you attempt to arm when a fault exists within
the system, the system will enter selected arm mode without further notification about
fault events.
Factory Default is set to
Confirm
.
Tamper Alarm
Away Arm:
Tamper alarm will only be activated when tamper switch is triggered under
Away Arm mode (Tamper event will still be reported normally in Home/Disarm mode).
Always:
Tamper alarm will be activated whenever tamper switch is triggered.
Factory Default is set to
Away Arm
.
Entry Timer Extend
Off:
When set to Off, if an Entry Delay countdown is activated and the Control Panel is