■Maintenance
Replacing the fan filter
There is a dust suction fan under the adhesive gel sheet plate in
the lower section of the cabinet. When the fan filter gets clogged
with the dust collected, the dust suction capability of the fan will
be decreased, and cause dust scattering.
During the process of washing the adhesive gel sheet, check the
condition of the fan filter, and if the filter is clogged, replace it with
a new filter.
Maintenance of Ionizer
Dirt and wear in the needle electrode can deteriorate the performance of this ionizer. Clean the
electrode every 300 hours of use (= approximately 1.5 month, based on calculation of use for 8
hours per day). If the electrode is not kept in an optimum condition, the performance will drop and
product life might shorten as well.
If the unit is used for a long period of time, the tip of the needle electrode may wear out and
consequently static erasing efficiency will decrease. In such case, replace the needle electrode
with a new one. It is recommended that the needle electrode be replaced every 1,200 hours of
operation (= approximately 6 months based on calculation of use for 8 hours per day).
Keep the unit in good working condition by measuring its ion balance and ion output regularly as a
means for checking for a drop in capacity.
⚠
CAUTIONS
Do not
disassemble
Do not perform any maintenance on the N-3 except for maintenance and
replacement of the electrode.
●
Remember
Before cleaning the electrode, shut off power and air supply at the source
and disconnect the air hose.
Prohibited
Do not wipe the ionizer with detergent or solvent. Substances of the sort
can cause cracking and result in electric shock or breakdown.
Do not wet
Do not wet the N-3. Exposure to moisture can result in electric shock or
breakdown.