Installation
Compressed air piping
⚠
CAUTION
●
Remember
Be sure to use an air hose with sufficient pressure resistance performance.
A hose without pressure resistance could burst or leak air.
Compressed air used
This unit requires that clean compressed air be supplied
to the dust removal air blower
Supply air within the pressure range of 0.1 to 0.6 MPa.
Use an air drier to remove the moisture from the air.
(The dew point temperature is -15°C or lower.)
Use mist separator (0.3 m) to remove the impurities from the air.
Supply air within the temperature range of 5 to 40 °C
Hose used
Use an air hose with sufficient pressure resistance performance
(outside diameter 8 mm x inside diameter 6 mm).
Hose connection
A one-touch hose coupling (air supply port) is provided on the lower left at the back of the body.
Connect the air hose to this.
Flow rate adjustment
A flow rate adjusting valve (FLOW CONTROL) is provided on the lower left
at the backside of the body. Adjust the rate of the discharged air as necessary.
Pre-use inspection
Pre-use product inspection
Before using the product, make sure there are no problems with it, the power adapter, etc. Make sure
there is no damage, and no loose of screws or connectors.