39
Removal
Removal
When removing this product, first make sure the surrounding area and other workers are safe.
⚠
CAUTION
●
Unplug
power cable
To prevent electrical shock accidents and operational mistake accidents during
the product removal work, be sure to unplug the power cord from the outlet.
●
Remember
When disconnecting a compressed air hose, be sure to first shut off the source
of the compressed air.
In addition, the compressed air inside the air hose could spray out when the air
hose is disconnected, so keep the hose away from the face, etc., when
disconnecting it.
●
Remember
To keep the unit from falling over, do not climb on the hood or dust collector or
place heavy objects on them.
●
Remember
Check the following, being aware of the weight of the product.
·
Be sufficiently careful that no part of the body, especially fingers and toes,
will be caught underneath the product while it is being removed or moved.
·
Make sure the product does not fall over while it is being removed or moved.
·
Do not move the product while an object is set on its hood. The object could
fall off of the hood.
Disposal
Disposal
When disposing of this product, dispose of it properly in accordance with the pertinent laws and local
regulations.
Replacement Parts
Replacement Parts
There are 3 consumable parts that can be replaced by the customer.
Check the model and lot No. and then purchase the parts through the store where the product was
purchased.
○Adhesive gel sheet
No. IPC-A4G
○Electrode Needle
No. GN-H (Optional dedicated needle electrode screwdriver G-7DR for
replacement of needle electrode)
○unwoven fan filter
IPC-A4F
For information about the replacement procedure, refer to the “Maintenance” item in this manual.