Figure 2.5 One-Line Diagram of Vertiv™ VRC-S split Connection - EMEA (without Liebert® GXT5)

2 Introduction

13

Vertiv™| VRC-S User Manual

Summary of Contents for VRC-S

Page 1: ...VRC S User Manual...

Page 2: ...mages resulting from use of this information or for any errors or omissions Refer to other local practices or building codes as applicable for the correct methods tools and materials to be used in per...

Page 3: ...the Rack Cooling Unit Vertiv VRC S with VCR Split 24 4 5 Install the Vertiv Vertiv VRC S with Vertiv VRC Split 24 4 6 Connect Power to the Backup Fan 24 4 7 Connect Power to the Condensate Pump 25 4 8...

Page 4: ...0 V NAM 44 8 4 Vertiv VRC S with VRC split lee temp 208V NAM 46 8 5 Vertiv VRC S with VRC self contained 230V EMEA 48 8 6 Vertiv VRC S with VRC split and VRC S with VRC split lee temp 230V EMEA 49 8 7...

Page 5: ...r rack equipment should be installed in the positions just above the Vertiv VRC then installing lighter equipment in the upper positions WARNING Risk of shock loading Can cause equipment damage The Ve...

Page 6: ...t suitable to fit below the skid and or unit to prevent exterior and or underside damage NOTICE Risk of improper storage Keep the unit upright indoors and protected from dampness freezing temperatures...

Page 7: ...ure to do so may result in serious injury or death Rack PDU units contain no user serviceable parts other than the field replaceable plastic carrier not installed on all models that is designed to be...

Page 8: ...d use the UPS in the following environments Temperature 32 F 122 F 0 C 50 C relative humidity 0 to 95 Out of direct sunlight Away from heat source Stable surface not subject to vibrations or shocks Aw...

Page 9: ...watches rings and other metal objects Use tools with insulated handles Wear rubber gloves and boots Do not lay tools or metal parts on top of batteries Disconnect charging source prior to connecting o...

Page 10: ...1 Important Safety Instructions 6 This page intentionally left blank Vertiv VRC S User Manual...

Page 11: ...and less than 80 relative humidity non condensing Operating the Vertiv VRC S in extreme environments may cause condensation inside the cabinet The VRC S is not environmental neutral The user is encour...

Page 12: ...UPS is installed it should be installed immediately above the Vertiv VRC Installing the UPS higher in the rack could result in a tipping hazard 2 3 Vertiv VRC Characteristics The Vertiv VRC cooling un...

Page 13: ...em UPS that continuously conditions and regulates its output voltage The Liebert GXT5 supplies microcomputers and other sensitive equipment with clean sine wave input power Upon generation AC power is...

Page 14: ...2 5 Vertiv VRC S System Connections Figure 2 2 One Line Diagram of Vertiv VRC S self contained Connection NAM without Liebert GXT5 2 Introduction 10 Vertiv VRC S User Manual...

Page 15: ...Figure 2 3 One Line Diagram of Vertiv VRC S self contained Connection EMEA without Liebert GXT5 2 Introduction 11 Vertiv VRC S User Manual...

Page 16: ...Figure 2 4 One Line Diagram of Vertiv VRC S self contained Connection EMEA with Liebert GXT5 2 Introduction 12 Vertiv VRC S User Manual...

Page 17: ...Figure 2 5 One Line Diagram of Vertiv VRC S split Connection EMEA without Liebert GXT5 2 Introduction 13 Vertiv VRC S User Manual...

Page 18: ...Figure 2 6 One Line Diagram of Vertiv VRC S Split Connection EMEA with Liebert GXT5 2 Introduction 14 Vertiv VRC S User Manual...

Page 19: ...Figure 2 7 One Line Diagram of Vertiv VRC S Split Connection NAM without Liebert GXT5 2 Introduction 15 Vertiv VRC S User Manual...

Page 20: ...2 Introduction 16 This page intentionally left blank Vertiv VRC S User Manual...

Page 21: ...impact damage Store the unit in the original packaging indoors in an area protected from excessive dirt debris and contact damage until final installation Observe the following requirements and the c...

Page 22: ...ls shipped with the Vertiv VRC S They can be found attached to the interior of the Vertiv VR rack Cut the plastic wrapping from the rack using a knife along the corrugated padding to prevent damaging...

Page 23: ...rtiv VR a 19 in EIA server rack will have these components factory installed Thermal separation Rack closing kit Sensors for temperature and door contact Backup fan Geist rPDU factory programmed Liebe...

Page 24: ...splay and Display Magnetic Box 10 m Cable of Display L shape Mounting Rail Kit Cage Nuts M6 Pan Head Screws M6x12 Torx T30 Center Screws M5x12 Torx T20 USB Converter Cable Side Panel Front Panel Manua...

Page 25: ...v VRC manual before Section 4 1 Install the filter in the Vertiv VRC The cooling unit has a filter on the top rear that collects particulates from the return air going back into the Vertiv VRC The bra...

Page 26: ...to help cooling air circulate efficiently inside the rack equipment section of Vertiv VRC S Cage nuts should have been attached to the rails before the Vertiv VRC was inserted into the cabinet Air ba...

Page 27: ...Figure 4 1 Air Barriers 800 mm 31 5 in Figure 4 2 Attach Air Baffles 800 mm 31 5 in Rack 4 Installation 23 Vertiv VRC S User Manual...

Page 28: ...manual NOTE Piping between the indoor and outdoor units must be routed so that it does not block the IT space above and does not extend into the space between the EIA rails 4 6 Connect Power to the Ba...

Page 29: ...on the factory installed Geist rPDU for proper operation The Geist rPDU is marked to facilitate proper connection To connect power to the condensate pump 1 Connect the power cord to the condensate pum...

Page 30: ...r the door or laid on the Vertiv VRC If the display is to be placed on the cooling unit simply attach the 20in 50cm communication cable to the rack and to the rear of the cooling unit as shown Figure...

Page 31: ...ables for the local display and the fan 1 Open the rear door of the Vertiv VRC S 2 Route the local display and fan cables around the outside edge of the fan housing and up to the top of the door 3 Use...

Page 32: ...bled permitting monitoring and managing the Vertiv VRC over a network Use the supplied cable to set up the connection the cable has an RJ 45 connector on one end and a USB connector on the other To co...

Page 33: ...ent air The Vertiv VRC S includes a flexible duct and two ceiling tiles one to move warm air from the Vertiv VRC C into the ceiling or and adjacent area through the duct The second tile is for make up...

Page 34: ...remove packaging from or prepare the unit for installation Vertiv recommends installing equipment in the Vertiv VR from bottom to top to promote a lower center of gravity All equipment must be install...

Page 35: ...ertiv Intelligence Director which is embedded in the Geist rPDU 5 3 1 Changing Settings with the Geist rPDU Using the Geist rPDU to monitor and manage the Vertiv VRC S requires connecting the rPDU to...

Page 36: ...ngs Item Description 1 Component Status Column 2 Change Configuration Settings Icon 3 Component Name 4 Current Readings 5 Additional Information Table 5 1 Geist rPDU Sensor Page Vertiv VRC Settings De...

Page 37: ...DU and Liebert GXT5 In case of versions with integrated Liebert GXT5 the aggregation function in the GeistrPDU web UI needs to be enabled Geist rPDU Manual for more information Figure 5 2 Aggregation...

Page 38: ...5 Operation 34 This page intentionally left blank Vertiv VRC S User Manual...

Page 39: ...the maximum rated value The Vertiv VRC s maximum load at 30 C 86 F is 3 3 kW the Vertiv VRC s cooling module is rated to remove 3 5 kW worth of heat Fan malfunction Contact Vertiv Technical Support Co...

Page 40: ...representative about obtaining a Vertiv Geist SwitchAir Heat sensor is incorrectly programmed Reprogram the high temperature setpoint via the rack PDU network card or contact Vertiv Technical Support...

Page 41: ...hen a UPS general alarm appears Table 6 3 Audible alarm Descriptions NOTE When an alarm is indicated an alarm message is logged See Liebert GTX5 User Manual that describes the alarm messages When a fa...

Page 42: ...the LCD select Main Menu About PROBLEM CAUSE SOLUTION UPS fails to start UPS is short circuited or overloaded Ensure UPS is Off Disconnect all loads and ensure nothing is lodged in output receptacles...

Page 43: ...updated in slave boards updt IMD 02 IMD 03 IMD 3 Firmware update in progress rset dflt IMD 02 IMD 03 IMD 3 Following user action rset Reset will appear during a parameter reset sequence During a param...

Page 44: ...tion Contact Vertiv Technical Support LowPressure Insufficient air flow Remove obstruction or debris from air inlets Fan malfunction Contact Vertiv Technical Support EEV malfunction Contact Vertiv Tec...

Page 45: ...6 mm 1385 mm 84 in 24 6 in 54 5 in 2396 mm 626 mm 1385 mm 94 3 in 24 6 in 54 5 in 2396 mm 826 mm 1385 mm 94 3 in 32 5 in 54 5 in rPDU Pre installed in rack NU30021 rPDUsub type Switched rPDUtype Outle...

Page 46: ...t 419 kg 924 lb 361 kg 796 lb 397 kg 876 lb 437 kg 964 lb Sound At 60 fan speed and 40 compressor speed 52 5 dBA 1 m 52 5 dBA 1 m 52 5 dBA 1 m 52 5 dBA 1 m Rack dimensions U H W D 42U 2000 mm 800 mm 1...

Page 47: ...2 SMTP SMTPS DHCP SNMP v1 v2c v3 LDAP NTP SSH and Syslog Certifications Agency approvals UL c UL Listed 60950 RoHS Compliant FCC Part 15 Class A Conformance UL c UL Listed 60950 RoHS Compliant FCC Pa...

Page 48: ...mm 626 mm 1385 mm 84 in 24 6 in 54 5 in 2396 mm 626 mm 1385 mm 94 3 in 24 6 in 54 5 in 2396 mm 826 mm 1385 mm 94 3 in 32 5 in 54 5 in rPDU Pre installed in rack NU30021 rPDUsub type Switched rPDUtype...

Page 49: ...densate pump tube length 7 5 m 24 ft NOTE Condenser will be shipped separate to customer Split System Condensing Unit VRC351KIT Input power hardwired L1 L2 L3 G Voltage Frequency 208 230 Vac 60 Hz Ful...

Page 50: ...ched rPDUtype Outlet Level Monitoring Outlet Level Monitoring Voltage 208 V 208 V Input current 30 A 30 A Regularoty derated input current North America 24 A 24 A rPDUrated maximum 4 9 kW 4 9 kW Horiz...

Page 51: ...PDU Condensate pump tube length 7 5 m 24 ft Certifications UL 1995 CSA 22 2 NO 236 11 NOTE Condenser will be shipped separate to customer Split System Condensing Unit VRC351KIT Input Power hardwired L...

Page 52: ...mm 94 3 in 24 6 in 54 5 in 2396 mm 826 mm 1385 mm 94 3 in 32 5 in 54 5 in rPDU Pre installed in rack GU30017L Category Switched Sub Category Outlet Level Monitoring EC Voltage 200 240 V Current 32 A V...

Page 53: ...Us VRCS3350 230VS VRCS3350 230VSL VRCS3300 230VS VRCS3300 230VSL VRCS3307 230VS VRCS3307 230VSL VRCS3357 230VS VRCS3357 230VSL Configured system weight 270 kg 595 lb 225 kg 496 lb 261 kg 575 lb 288 kg...

Page 54: ...Syslog TACACS Certifications Agency approvals CEMarked Complies with EN 55032 and EN 55024 Complies with IEC 60950 1 CB Certificate Available RoHS Compliant RCM Mark EMC Only China RoHS C Mark Split S...

Page 55: ...335 2 40 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 RoHS Compliant EN 50581 Split System Condensing Unit VRC302KIT Input power Hardwired L N PE Voltage Frequency 230 Vac 50 60 Hz Full Load Ampera...

Page 56: ...94 3 32 5 54 5 Certifications CEMarked rPDU Pre installed in rack GU30017L Category Switched Sub Category Outlet Level Monitoring EC Voltage 200 240 VAC Current 32 A VA per Input 7 3 kW 230 V Frequenc...

Page 57: ...EN 61000 3 2 EN 61000 3 3 RoHS Compliant UPS Pre installed in rack GXT5 6000IRT5UXLE Rating 6000 VA 6000 W system limited IT load max 3 5 kW Form factor 5U Unit dimensions HxDxW Inches 217 mm x 630 mm...

Page 58: ...Temperature 15 C to 40 C 5 F to 104 F Relative Humidity 0 95 non condensing Operating Elevation Up to 3 000 m 9 842 5 ft at 25 C 77 F without derating Audible Noise 55 dBA at 1 meter from the front 5...

Page 59: ...32 5 54 5 2134mm 626mm 1385mm 84 24 6 54 5 2396mm 626mm 1385mm 94 3 24 6 54 5 2396mm 826mm 1385mm 94 3 32 5 54 5 rPDU Pre installed in rack GU30017L rPDUsub type Switched rPDUtype Outlet Level Monito...

Page 60: ...nit VRC302KIT Input Hardwired L N PE Voltage Frequency 230 Vac 50 60 Hz Full Load Amperage FLA 6 5 A Refrigerant type pre charged R410A outdoor unit 900 g 1 98 lb Dimensions H W D Inches 527 mm 282 mm...

Page 61: ...16 9 Unit weight 70 8 kg 156 lb Input AC Parameters Operating Frequency Nom 50 or 60 Hz factory default is 50 Hz User configurable VAC 200 208 220 230 240 VAC Adjustable using operation display confi...

Page 62: ...le Noise 55 dBA at 1 meter from the front 50 dBA at 1 meter from rear or sides Agency Safety IEC62040 1 2008 version GS mark EMI EMC C Tick EMC IEC EN AS 62040 2 2nd Ed Cat 2 Table 6 ESD IEC EN EN6100...

Page 63: ...rflowis unobstructed External ventilation is adequate to supply makeup air for the Vertiv VRC System is not closed External air is within a temperature range of 64 4 F 86 F 18 C 30 C condensing and le...

Page 64: ...9 Appendices 60 This page intentionally left blank Vertiv VRC S User Manual...

Page 65: ...Vertiv VRC S User Manual...

Page 66: ...e trade names trademarks or registered trademarks of their respective owners While every precaution has been taken to ensure accuracy and completeness here Vertiv Group Corp assumes no responsibility...