6
vertilux.com
© 2019. Vertilux, Ltd. All Rights Reserved. Last revised: February 2019.
2.
Press and hold the
blue button
until you reach
step 4.
TILTING MOTOR
BLUE BUTTON
3.
On the wall control, press either
direction
button
. If the button you pressed does not make
the carriers rotate, try the opposite
direction button
. Press the
stop button
when the
carriers are aligned and set at
0°
of the track
(fully closed position)
(fig. 5)
*.
Remember which
direction button
you selected in
this step.
DIRECTION BUTTON
STOP BUTTON
TILTING MOTOR
RED BUTTON
OPPOSITE DIRECTION
BUTTON
5.
On the wall control, press the
opposite
direction button
to make the carriers return to
the original starting position at 90° of the rail,
(open position) (
fig. 4
).
The first tilting limit has now been set.
4.
You can now release the
blue button
.
TILTING MOTOR
BLUE BUTTON
6.
Press and hold the
red button
until you reach
step 8.
7.
Press the
opposite direction button
of the one
selected in step 3.
The slats will rotate to the opposite direction of
the first tilting limit that was set.
Press the
stop button
when the slat is aligned
and set to 0° of the track
(fig. 5)
*.
OPPOSITE DIRECTION
BUTTON
STOP BUTTON
TILTING MOTOR
RED BUTTON
8.
You can now release the
red button
.
On the wall control, press the same
direction
button
as selected in step 3.
The other tilting limit has now been set.
DIRECTION
BUTTON
Summary of Contents for VTi 6-710-VB-00110