13. Trouble Shooting
Cont.
No Hot Water from Hot Tank
Possible Causes
Solution
1. Cooler not plugged in
Make sure power cord is plugged
into wall socket
2. Power switch not on
Make sure Hot power button on front
panel is on and illuminated
3. Electrical terminal
Check to see that both wires are
disconnected
connected to the heating element
terminals. These are located at the
bottom of the tanks
4. Heating element failure
Check for continuity across hot tank
due to scaling
heater terminals. To do this, unplug
unit from wall power. Disconnect one
of the connector at the heating element
terminals (at bottom of tank). Using
an ohm meter, check for continuity
across the 2 terminals. If there is no
continuity (open), the tank must be
replaced.