Versiton KGC-460 User Manual Download Page 40

5. Redundant Ring Application 

5.1 Auto Multi-Ring Technology for 4-Port Switch Mode 

Auto Multi-Ring Technology was developed especially for switches connected in ring topology which 

needs redundant support when any failure occurs in ring. For large network, more than one ring 

connections are very common. Auto Multi-Ring Technology implementation can support more than 

one ring connection within a switch. It is also able to work with RSTP support concurrently in the 

switch. 

 

Some basic information is: 

 

Supports up to five rings in one switch 

 

Supports up to 30 member switches in one ring 

 

Provides fast response time than RSTP protocol 

 

Works with RSTP protocol concurrently within one switch 

 

The following figure illustrates a ring configuration composed of the devices connected via fiber: 

 

-40- 

Summary of Contents for KGC-460

Page 1: ...KGC 460 KGC 460 HP Industrial Managed Multi function Gigabit Ethernet Media Converters Firmware Rev1 0 up User s Manual DOC 141231 1...

Page 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For m...

Page 3: ...interference and 2 This device must accept any interference received including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipmen...

Page 4: ...Connections 20 2 9 Making Fiber Connection 21 2 10 Making PoE PSE Connections KGC 460 HP 23 2 11 LED Indication 24 3 Manage the Device 26 3 1 IP Address Password 26 3 2 Configuring IP Address Passwor...

Page 5: ...5 5 Redundant Ring Application 40 5 1 Auto Multi Ring Technology for 4 Port Switch Mode 40 5 2 Redundant Ring Applications with industrial standard RSTP protocol 41...

Page 6: ...speed SFP slots for 100Base FX 1000Base X The device is featured the function modes Dual media converts mode Dual media converters sharing redundant fiber uplink mode Fiber to fiber media converter mo...

Page 7: ...re and configured port link down Green Ethernet power saving 802 3az Energy Efficient Ethernet EEE support Optional high power PoE PSE function on copper ports Management HTTP HTTPS SSHv2 CLI telnet C...

Page 8: ...1 2 Product Panels The following figure illustrates the front panel and rear panel of the device KGC 460 HP Front panel KGC 460 Front panel 8...

Page 9: ...ctors Shielded RJ 45 jacks Pin assignments Auto MDI MDI X detection Configuration Auto negotiation or software control Transmission rate 10Mbps 100Mbps 1000Mbps Duplex support Full Half duplex Network...

Page 10: ...92 supported Flow control IEEE 802 3x pause frame base for full duplex operation Back pressure for half duplex operation Terminal Block Connector DC power input Screwed euro terminal block contacts Op...

Page 11: ...g Temperature Typical 30 75 Storage Temperature 40 85 Relative Humidity 5 90 non condensing 60 75 with 1m s air flow Electrical Approvals FCC Part 15 rule Class A CE EMC Class A EN 61000 6 4 EN 61000...

Page 12: ...the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The produ...

Page 13: ...steps to mount the switch onto a DIN rail are 1 Install the mounting bracket onto the switch unit as shown below 2 Attach bracket to the lower edge of the DIN rail and push the unit upward a little b...

Page 14: ...Dimensions 14...

Page 15: ...nting bracket The bracket supports mounting the switch on a plane surface securely The mounting steps are 1 Install the mounting bracket on the switch unit 2 Screw the bracket on the switch unit 3 Scr...

Page 16: ...Dimensions 16...

Page 17: ...ations Applications Power per PSE port DC working voltage General 8V 60VDC PoE 15 4W max 45V 57VDC Typical 48V High power PoE PoE 35W max 45V 57VDC 52V up for 35W WARNING The 48VDC power supply is not...

Page 18: ...rm Relay output pins and logic 4 5 Pin NO NO Alarm relay output NO Normal Open contacts Open normal Shorted Alarm 5 6 Pin NC NC Alarm relay output NC Normal Closed contacts Shorted normal Open Alarm E...

Page 19: ...ch without turning off the power Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are Operatio...

Page 20: ...e for MDI to MDI X connection It simplifies the cable installation Auto negotiation Function The ports are featured with auto negotiation function and full capability to support connection to any Ethe...

Page 21: ...transceiver into SFP slot the steps are 1 Turn off the power to the switch 2 Insert the SFP fiber transceiver into the SFP slot Normally a bail is provided for every SFP transceiver Hold the bail and...

Page 22: ...r SFP Port 9 and Port 10 The options are Auto Auto detection for the type of the installed SFP transceiver by reading DDM data 100Mbps transceiver Non auto negotiation forced 100Mbps full duplex 1000M...

Page 23: ...5 7 8 of the cable The maximum distance supported is 100 meters 3 The power voltage supplied to the switch must be within the range as specified in section 2 5 to make PoE function working The PSE por...

Page 24: ...Initialization completed with no error operating in 2MC mode Green BLINK Initialization completed with no error operating in F2F MC mode Yellow ON Initialization completed with no error operating in 2...

Page 25: ...3 Port 4 SPEED_LED Port speed link status Green ON A 1000Mbps link is established Yellow ON A 100Mbps link is established BLINK Activity status OFF Port link is down G Y BLINK Green and yellow light...

Page 26: ...2 255 255 255 0 The device uses local authentication instead of RADIUS authentication with factory defaults Fixed Username admin Default password No password is required with factory default However t...

Page 27: ...ers Delete user_name Refer to Operation manual for telnet management 3 3 Configuring IP Address via Web Interface Start Web Browser Start your browser software and enter the default IP address for the...

Page 28: ...No password is required Click OK to login into the device Web Page after a Successful Login Select Configuration System IP to configure IP address Configuration Description 28...

Page 29: ...will relay DNS requests to the current configured DNS server on DUT and reply as a DNS resolver to the client device on the network Save Click to save the changes Reset Click to undo any changes made...

Page 30: ...tination ipv6_addr SNMP Trap Authentication Failure enable disable SNMP Trap Link up enable disable SNMP Trap Inform Mode enable disable SNMP Trap Inform Timeout timeout SNMP Trap Inform Retry Times r...

Page 31: ...SNMPv3 agent USM User based Security Model user table for SNMPv3 VACM View based Access Control Model Viewer table for SNMPv3 Group table for SNMPv3 Accesses group table for SNMPv3 3 6 SNMP MIBs The...

Page 32: ...ship Discovery MGMD MIB IEEE 802 1 MSTP MIB IEEE 802 1AB LLDP MIB IEEE 802 1X Port Access Entity PAE MIB TIA 1057 LLDP Media Endpoint Discovery MED MIB IEEE 802 1 Q BRIDGE MIB Private SFPDDM MIB One p...

Page 33: ...ration as shown below The functions of the SW switch settings are 1 Hardware 1 The operating mode is determined by SW1 and SW3 settings 2 LFPT function configuration which is used for all media conver...

Page 34: ...s a copper cable a multi mode fiber cable or single mode fiber cable They also may be in different speeds The Link Fault Pass Through LFPT function is an import optional function to a media converter...

Page 35: ...uto for all ports Software configuration IGMP Disabled Software configuration LLDP Disabled Software configuration DDM Available Available F2F MC PoE 2 Enabled Auto Software configuration Management c...

Page 36: ...media converter mode As configured the device becomes two media converters in one box Port 1 and Port 3 are ports of MC1 converter Port 2 and Port 4 are ports of MC2 converter Both media converters ar...

Page 37: ...2 have no logic connection to Port 3 and Port 4 under this mode Multi mode fiber MMF to single mode fiber SMF conversion is the most popular application with this operating mode LFPT function option...

Page 38: ...port P3 4 is LACP compliant Both P3 and P4 are operating at the same time normally When any is link fault the other will take over the transmission duty for both MC1 and MC2 LFPT function is also avai...

Page 39: ...CLI telnet CLI console SNMP v1 v2c v3 RMON DHCP DHCPv6 client DHCP relay DNS client NTPv4 IPv6 support System Syslog Configuration down upload Software upload Security functions NAS 802 1X MAC based...

Page 40: ...y common Auto Multi Ring Technology implementation can support more than one ring connection within a switch It is also able to work with RSTP support concurrently in the switch Some basic information...

Page 41: ...same time 5 2 Redundant Ring Applications with industrial standard RSTP protocol It also can be done to support a ring connection using industrial standard RSTP function and establish a backup path In...