4. Function Modes
The device can be configured to perform one of the following function operating modes:
Dual media converts mode
Dual media converters sharing redundant fiber uplink mode
Fiber to fiber media converter mode
4-port switch mode
4.1 Operating Mode Configuration
One setting SW is provided for operating mode configuration as shown below:
The functions of the SW switch settings are:
1 Hardware
1.
The operating mode is determined by SW1 and SW3
settings.
2.
LFPT function configuration which is used for all media
converter modes is determined by SW4 setting.
3.
All software setting configurations are ignored.
4.
The operation status can be monitored via software
management interface.
SW1
0 Software
1.
Settings of SW2 SW3 SW4 are ignored.
2.
The operating mode and LFPT function configuration are
determined by configuration via software interfaces.