Note:
1.
Only up to four device units can be cascaded to receive power from one main power input source.
2.
The maximal length of the power wire is 1 meter.
2.6 Alarm Relay Output
Alarm relay output is provided for reporting failure events to a remote alarm relay monitoring system. The
replay output is provided with three contacts (support two logic types) in the terminal block connector next
Vdc interfaces.
Alarm Relay output pins and logic:
4 5
Pin
NO NO
Alarm relay output, NO (Normal Open) contacts
Open: normal, Shorted: Alarm
5 6
Pin
NC NC
Alarm relay output, NC (Normal Closed) contacts
Shorted: normal, Open: Alarm
Either pair can be used depending on the logic requirement for the relay monitoring system.
Use the provided 3P terminal plug for signal wiring and plug into the contacts.
Alarm Events
Input power failure
Specific port link down (The specific ports can be configured by software.)
Note: Be sure the voltage applied on the contacts is within the specification of 30VDC/1A max. or
120VAC/0.5A max.
2.7 Reset Button