16
2
Pressure
regulator
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
REGULATOR COVER
CONVERSION TO LP/PROPANE GAS (OR CONVERSION BACK TO THE
ORIGINAL GAS - NATURAL GAS)
Every range is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.
CAUTION: Save the orifices removed from the appliance for future use.
SETTING THE PRESSURE REGULATOR
The pressure regulator is accessible by opening the pivoting panel (fig. 2.6); the pressure regulator is
positioned on the rear right side of the range (fig. 2.7).
To set the pressure regulator
(fig. 2.7):
1. Unscrew the regulator cover.
2. Unscrew the “
A
” component, reverse and screw it according to the LP/PROPANE (or NATURAL GAS)
regulation.
Fig. 2.6
Fig. 2.7
Summary of Contents for VEFSGE 304 SC
Page 23: ...23...