10
1
LEVELLING THE RANGE
The range is equipped with 4 LEVELLING FEET and may be levelled by screwing or
unscrewing the feet (figs. 1.6 - 1.7).
It is important to observe the directions of figures 1.6, 1.8a, 1.8b.
Fig. 1.8b
Fig. 1.8a
Fig. 1.7
Fig. 1.6
Supplied with the range
in a separate kit
Supplied with the range
in a separate kit
0”
0 mm
+ 5/16”
+ 8 mm
+ 5/16”
+ 8 mm
+ 11/16”
+ 17.5 mm
Fig. 1.9
Dotted line showing the position
of the range when installed
ANTI-TIP STABILITY
DEVICE FIXING
Anti-tip stability
device
Rear left
feet of range
3” 15/64
(82 mm)
YOU MUST USE STABILITY
ANTI TIP BRACKET TO
PREVENT UNIT FROM
TIPPING.
ANTI-TIP STABILITY DEVICE INSTALLATION INSTRUCTIONS
1. The anti-tip bracket has to be attached as shown on figure below (only rear left side),
it has to be fixed on the floor OR on the rear wall by no. 4 (four) suitable screws (not
supplied). Alternatively the anti-tip bracket can also be fixed on the floor AND on the
rear wall by no. 8 (eight) suitable screws (not supplied).
2. After fixing the anti-tip bracket, slide range into place. Be sure the rear left foot slides
under the anti-tip bracket attached.