8

Accessories/ Replacements

Item

Order Code

Fluorescence/UV Quartz Cuvette

CUV-QUARTZ-FUV

Spectrophotometer Optical Fiber

VSP-FIBER

Mini USB Cable

CB-USB-MINI

Replacement Power Supply for Ultraviolet
Range (UV-VIS) Spectrophotometers

VSP-UV-PS

Warranty

Warranty information for this product can be found on the Support tab at

www.vernier.com/gdx-spec-fuv

General warranty information can be found at

www.vernier.com/warranty

Federal Communication Commission Interference Statement

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

FCC Caution

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference and

(2) this device must accept any interference received, including interference that may cause undesired operation

RF Exposure Warning

The equipment complies with RF exposure limits set forth for an uncontrolled environment. The antenna(s) used for this transmitter must not
be co-located or operating in conjunction with any other antenna or transmitter. You are cautioned that changes or modifications not
expressly approved by the party responsible for compliance could void your authority to operate the equipment.

IC Statement

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

(1) this device may not cause interference, and

(2) this device must accept any interference, including interference that may cause undesired operation of the device.

Industry Canada - Class B

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set

out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of Industry Canada. Operation is subject to the
following two conditions: (1) this device may not cause interference, and

(2) this device must accept any interference, including interference that may cause undesired operation of the device.

To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically
radiated power (e.i.r.p.) is not more than that permitted for successful communication.

RF exposure warning:

The equipment complies with RF exposure limits set forth for an uncontrolled environment. The antenna(s) used for

this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes :

(1) l’appareil ne doit pas produire de brouillage, et

(2) l’appareil doit accepter tout interférence radioélectrique, même si cela résulte à un brouillage susceptible d’en compromettre le
fonctionnement.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe B prescrites dans la
norme sur le matériel interférant-brouilleur: “Appareils Numériques,” NMB-003 édictée par industrie Canada. L’utilisation est soumise aux
deux conditions suivantes:

(1) cet appareil ne peut causer d’interférences, et

(2) cet appareil doit accepter toutes interférences, y comprises celles susceptibles de provoquer un disfonctionnement du dispositif.

l

Do not remove or modify any of the installed safety components of this
device. Doing so will create an unsafe operating condition and will void the
product warranty.

l

No user-serviceable parts are in this device. Do not attempt to open or modify
this device. Contact Vernier for all repairs and service including lamp
replacement.

l

Handle the device with care. This instrument can be damaged if it is dropped.

l

Do not use this instrument if it is damaged in any way. Contact Vernier
Technical Support for troubleshooting and technical assistance.

l

Do not use this instrument for clinical or diagnostic procedures.

Troubleshooting

1. If you plan on only taking fluorescence data, the power cable does not need to

be attached, nor does the power switch need to be on. This will help save your
deuterium lamp for absorbance measurements.

2. In fluorescence measurements, the inner-filter effect is always a consideration.

The inner filter effect results in an apparent decrease in emission quantum
yield and/or distortion of bandshape as a result of reabsorption of emitted
radiation. To avoid this, it is best to perform fluorescence measurements on
samples that have an absorbance below 0.1.

Find troubleshooting tips here:

www.vernier.com/til/3918

Repair Information

l

The UV light source in the Go Direct Fluorescence/UV-VIS
Spectrophotometer is a deuterium lamp. The lifetime of this source is rated at
approximately 1000 hours. Lifetime is defined as the amount of time it takes
the lamp to decrease to 50% of its original output. Deuterium lamp life is also
inversely proportional to the number of ignitions, so it is best to limit the
number of times you ignite the bulb if you wish to prolong its life.

l

The deuterium lamp is covered by a one-year warranty or 1000 hours,
whichever comes first.

l

Contact Vernier for all repairs and service including lamp replacement.

l

No user-serviceable parts are in this device. Do not attempt to open the case of
the device. Do not attempt to change or repair the lamp. Doing so will create
an unsafe operating condition and will void the product warranty.

If you have watched the related product video(s), followed the troubleshooting
steps, and are still having trouble with your Go Direct Fluorescence/UV-VIS
Spectrophotometer, contact Vernier Technical Support at [email protected] or
call 888-837-6437. Support specialists will work with you to determine if the unit
needs to be sent in for repair. At that time, a Return Merchandise Authorization
(RMA) number will be issued and instructions will be communicated on how to
return the unit for repair.

Summary of Contents for Go Direct GDX-SPEC-FUV

Page 1: ...etooth icon is solid when sensor is connected via Bluetooth wireless tech nology Go Direct Fluorescence UV VIS Spectrophotometer Order Code GDX SPEC FUV Go Direct Fluorescence UV VIS Spectrophotometer...

Page 2: ...discharge tube To do so you will need to purchase the Vernier Optical Fiber order code VSP FIBER Measure Intensity of Light Emissions Insert the Vernier Optical Fiber into the spectrometer Connecting...

Page 3: ...of your screen 1 Connect the spectrometer following the steps in the Getting Started section of this user manual 2 Open Spectral Analysis 3 Select the appropriate Emissions experiment from the listed...

Page 4: ...he Meter screen tap Mode Change the mode to Events with Entry 2 Enter the Name e g Concentration and Units e g mol L Select OK 3 A message will appear warning you to either save or discard the full sp...

Page 5: ...ments the default settings work well There are five parameters listed in the dialog box l Sample Time This is similar to the shutter speed of a camera LabQuest automatically selects the proper sample...

Page 6: ...at a light source Click Click to end data collection Note The Spectrophotometer is not calibrated for measuring intensity l Option 1 The default option is to use a single 10 nm band This measures the...

Page 7: ...e Sample Time begin with 75 ms with subsequent reductions by 20 ms to a suitable value and decrease the Samples to Average to 1 Use the Stored Emissions Files in Logger Pro Logger Pro contains a folde...

Page 8: ...this transmitter must not be co located or operating in conjunction with any other antenna or transmitter Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio e...

Page 9: ...ensitive measurement device For best results use the cables that were provided Keep the device away from electromagnetic noise sources such as microwaves monitors electric motors and appliances Vernie...