10000836
11
Vermont Castings, Majestic Products RHE Natural Vent Insert
Operating Instructions
General Glass Information
Only ceramic glass approved for use in Majestic
fireplaces may be used for replacement on this
fireplace.
1. The use of substitute glass will void all product
warranties.
2. Care must be taken to avoid breakage of the glass.
3. Under no circumstances should this fireplace be
operated without front glass properly installed, or
with any cracked or broken glass. Replacement of
any glass assembly as supplied by the
manufacturer should be done by a licensed qualified
service person.
Louvre Removal
To remove top flat
louvre pull louvre up
and then lift out.
1.
2.
Louvre
Glass
Panel
FP444
Fig. 15 Louvre removal.
Glass Cleaning
It will be necessary to clean the glass periodically.
During start-up, condensation, which is normal, forms
on the inside of the glass and causes lint, dust and
other airborne particles to cling to the glass surface.
Also initial paint curing may deposit a slight film on the
glass. It is therefore recommended the glass be
cleaned two or three times with a non-ammonia
household cleaner and warm water (we recommend
gas fireplace glass cleaner). After that the glass should
be cleaned two or three times during each heating
season depending on the circumstances present.
Clean glass after first two weeks of
operation.
Glass Frame Removal
1. Remove the top louvre. (Refer to "Louvre Removal"
section)
2. Open the access door.
3. Remove two (2) machine screws from the bottom of
glass frame. (Fig. 16)
4. Lift up and unhook glass frame at the top.
Before remounting glass frame, brass
trim must be installed. Refer to instruc-
tions in "Frame Mounting" section.
Screws
Open Access Door
Machine Screws
Glass Frame
FP1373
Fig. 16 Remove glass frame.
Installation of Logs
1 . Remove front glass. (Refer to "Glass Removal"
section)
2.
Remove logs from packaging.
3.
Place rear log (JR4/KR4 or SR4) on rear bracket
(ensure log is seated properly, leveled and
centered to the unit), so it will not move from side to
side and is firmly positioned on the bracket.
4.
Slip front ember log (KR1or SR1) down in the front
deflector.
5.
Place front left log (JR2/KR2 or SR2) on top
burner, left side. Use log's bottom holes to locate it
into the left bracket log locator studs.
6.
Place front right log (JR3/KR3 or SR3) on top of
burner, right side. Use log's bottom holes to locate
it into the right bracket log locator studs.
7.
Place burner lava rock material on top of burner.
(Refer to Figs. 17, 18 & 19 for proper location).
8.
Place top left log (JR5/KR5 or SR5) onto locator
notches. Ensure log is secure.
9.
Place top right log (JR6/KR6 or SR6) onto locator
notches. Ensure log is secure.
Top logs must be placed properly into
notches.