10
10000836
Vermont Castings, Majestic Products RHE Natural Vent Insert
Operation of this fireplace when not
connected to a properly installed and
maintained venting system or tampering
with the vent safety shutoff system can
result in carbon monoxide (CO)
poisoning and possibly death.
Fan Kit
115 Volt, 60 Hz. 56W
The fan kit includes the following: fan, temperature
sensor, speed control and a 6 ft. cord. The following
explains how to start and set the fan for automatic
operation.
1. Plug in the electrical cord.
2. Start gas fire - see lighting procedures.
3. Turn on fan speed control.
4. Wait until the unit has warmed up sufficiently to
activate the temperature sensor.
5. Once fan starts, adjust speed control to desired fan
speed. The fan will now automatically come on
every time the fireplace is in operation. Should the
fan not be needed simply turn off the speed control.
The appliance, when installed must be
electrically connected and grounded in
accordance with local codes or, in the
absence of local codes, with the current
CSA C22.1 Canadian Electrical Code.
For U.S.A. installations, follow local
codes and the national electrical code,
ANSI/NFPA No. 70.
Should this fan require servicing, the
power supply must be disconnected. For
rewiring of any replacement compo-
nents refer to Figures 13 & 14.
Fan Removal Instructions
1. Turn off gas and electricity.
2. Remove the front glass.
3. Remove the logs.
4. Remove burner assembly and rear log support plate.
5. Remove the fan mounting nuts (2). (Fig. 13)
6. Slip off the electrical connector at the motor.
7. Lift out the fan.
8. To reinstall, reverse procedure.
Fan is installed
at the back of
the air intake
box
Stud
Fan Speed Control/Junction Box
Valve
Thermal Sensor is
attached to burner
base
FP1252
Fig. 13 Fan location.
Stud
FP394
Black
White
Ground
Speed
Control
Temperature Sensor
Fan
Fig. 14 Wiring diagram RN/RP.