8
1.6 HEARTHS
The hearth used with this product should extend 75mm in front of stove and 150mm either
side of the stove
1.7 SPILLAGE MONITORING SYSTEM
This appliance is fitted with a draft diverter and thermal switch. This is designed to shut the
fire off in the event of a partial or complete blockage of the flue causing a build up of
combustion products in the room in which the stove is operated.
The following are
important warnings relating to this spillage monitoring system
:-
1) The spillage monitoring system must not be adjusted by the installer.
2) The spillage monitoring system must not be put out of operation under any
circumstances.
3) When the spillage monitoring system is exchanged only a complete original
manufacturers part may be fitted. It is not possible to replace individual parts on this
appliance, only a complete assembly may be fitted.
1.8 FITTING THE REMOVEABLE HANDLE TO THE STOVE DOOR
The door handle which comes with the stove is designed to be removeable to prevent
overheating during long periods of use. To use the handle, simply slide the collar into
the door handle and open the doors. When you have either opened or shut the doors,
remove the handle and store in a safe place.
IMPORTANT NOTICE
:
PLEASE INFORM THE CUSTOMER THAT THIS
STOVE MUST NOT BE RUN WITH THE DOORS
IN THE OPEN POSITION, OR IF THE GLASS IS
BROKEN OR MISSING.
A LABEL STATING THIS MESSAGE IS ADHERED TO THE GLASS DOORS OF THE
APPLIANCE PLEASE ASK THE CUSTOMER TO REMOVE THIS LABELTO
ENSURE THAT THEY ARE AWARE OF THIS BEFORE LIGHTING THE STOVE FOR
THE FIRST TIME.