background image

20306756

380IDV Fireplace Insert

11

VENTING INSTALLATION 

Read  all  instructions  completely  and 

thoroughly before attempting installation. 

Failure  to  do  so  could  result  in  serious 

injury,  property  damage  or  loss  of  life. 

Operation  of  improperly  installed  and 

maintained venting system could result in 

serious injury, property damage or loss of 

life. 

INSTALLATION PRECAUTIONS

Consult local building codes before beginning the installa-

tion. The installer must make sure to select the proper vent 

system for installation. Before installing vent kit, the installer 

must read this insert manual and vent kit instructions.

Only a qualified installer/service person should install vent

-

ing system. The installer must follow these safety rules:

  Wear gloves and safety glasses for protection.

  Use extreme caution when using ladders or when 

on rooftops.

  Be aware of electrical wiring locations in walls and 

ceiling.

The following actions will void the warranty on your vent-

ing system:

  Installation of any damaged venting component.

 

Unauthorized modification of the venting system.

  Installation of any component part not manufactured 

or approved by Vermont Castings Group.

  Installation other than permitted by these instruc-

tions.

This  insert  must  be  vented  to  the 

outside.  The  venting  system  must 

NEVER  be  attached  to  a  chimney 

serving  a  separate  solid  fuel  burning 

appliance. Each gas appliance must 

use a separate vent system. Do not use 

common vent systems. 

W

ARNING

Failure to follow these instructions will 

void the warranty. 

NOTICE

W

ARNING

• 

Make  sure  the  exhaust  pipe  on  heater 

connects to exhaust portion of cap. At-

tach flex liners. 

Figure 6

• 

Do not crimp or rupture liner when bend

-

ing it into chimney offsets.

VENTING REQUIREMENTS

   The exhaust vent must reline the entire length of chim-

ney and terminate above chimney top.

   Vent must meet all vent manufacturer's requirements 

when installed.

   Make sure you have the following before installing 

unit:

380 Series:

  3" and 3" UL 1777 Listed gas liner for air inlet and 

exhaust.

   Vertical termination kit (AI31TK33A)

W

ARNING

FP2625
typical venting

Exhaust

Inlet

Maximum 12" 

(305 mm) Offset at 

Base of Insert

Maximum 

Height 

40' (12.9 m)

Minimum 

Height

10' (3 m)

FP2625

Figure 7 - 

Venting Unit

Summary of Contents for 380IDVNVSB

Page 1: ...amage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Thisappliancemaybeinstalledinanaftermarket permanently located manu...

Page 2: ...all On Off Switch 23 Installing Filigree Panels 23 Safety Barrier Installation 24 Operating Instructions 25 What To Do If You Smell Gas 25 Lighting Pilot for the First Time 25 Lighting Pilot 26 Lighti...

Page 3: ...ified service person The glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed combustion leakag...

Page 4: ...2014 CSA 2 33 2014 STANDARDS A manufactured home USA only or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such...

Page 5: ...ed home where not prohibited by local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer HIGH ELEVATIONS Input ratings are shown in BTU per hour and are certified wit...

Page 6: ...533 mm C 21 533 mm D 21 533 mm E 16 406 mm Figure 3 IDV Fireplace Insert Opening Dimensions C A D B FP2530 hearth dims E 27 702 mm 17 443 mm 10 264 mm 4 114 mm 8 221 mm 15 395 mm 29 749 mm 30 767 mm 2...

Page 7: ...ver obstruct the front opening of the insert Do not install in the vicinity where gasoline or other flammable liquids may be stored These units can be installed in a bedroom Refer to National Fuel Gas...

Page 8: ...arth The hearth must also extend to both sides of the face Figure 4 Mantel Clearances FP2623 Minimum clearances Max 13 Max 3 4 Min 9 Min 11 13 330 mm Maximum Depth Minimum 8 203 mm 22 559 mm Minimum 1...

Page 9: ...n a bedroom Please be aware of the large amount of heat this appliance pro duces when determining a location FP2624 insert placement Figure 5 Insert Placement For tight fits you may remove the manifol...

Page 10: ...your room is well ventilated OPEN ALL WINDOWS DURING INITIAL BURN OFF CURING PHASE Burn your insert for at least six 6 hours on HIGH the first time you use it Place the fan in the OFF position during...

Page 11: ...ing component Unauthorized modification of the venting system Installation of any component part not manufactured or approved by Vermont Castings Group Installation other than permitted by these instr...

Page 12: ...ltitude contact your dealer Failure to adjust air shutter properly may lead to improper combustion which can create a safety hazard Consult your dealer or installer if you suspect an improperly adjust...

Page 13: ...masonry or zero clearance fireplace FP2627 inlet exhaust reline Exhaust Inlet Recommended block off plate noncombustible metal Prevents odors from chimney entering room UL 127 Solid Fuel Z C Fire box...

Page 14: ...ex Vent to Manifold 4 Attach flex vent to manifold Figure 11 Seal with silicone and attach with screws FP2631 pull excess vent Excess Flex Vent Chimney Slack in Flex Vent Manifold FP2632 Figure 12 Pul...

Page 15: ...ator 9 08 External Regual tor Vent Pointing Down 100 gal min Propane LP Supply Tank FP1930 Figure 14 External Regulator with Vent Pointing Down Propane LP Only CAUTION Use only new black iron or steel...

Page 16: ...c Pressure Propane LP From External Regulator 11 w c to 13 w c Pressure 3 Minimum FP1931 gas connection 9 08 Approved Flexible Gas Line Supplied with Appliance Tee Joint Pipe Nipple Cap Figure 15 Gas...

Page 17: ...a soap and water solution or a gas sniffer 4 To adjust flame height turn HI LO knob to HI to get maximum pressure to burner Turn HI LO knob to LO to get minimum pressure 5 To check gas pressures at v...

Page 18: ...933 wall switch wiring Figure 17 Wiring Diagram for Wall Switch Sparker Thermocouple Piezo Igniter Thermopile Pilot Assembly Switch Millivolt Valve TH TP TH TP ON OFF Optional 15 Wall Switch Optional...

Page 19: ...place 3 Set glass frame aside WARNING Make sure the glass panel edges do not touch any metal parts during thermal ex pansion CAUTION Always use gloves when handling broken glass DANGER HOT GLASS WILL...

Page 20: ...pen front door of firebox 2 Break up rock wool ember material into dime sized pieces Place evenly as shown Do not exceed 1 layer Figure 18 3 Carefully remove the seven 7 logs from wrapping LG765 place...

Page 21: ...f right base log Figure 23 LG771 place right center log 5 Right Center Log 5 Figure 23 INSERT INSTALLATION LG772 place right top log 6 Right Top Log 6 Figure 24 LG773 Place top Y log 7 Top Y Log 7 Fig...

Page 22: ...four 4 hooks on back of surround with four 4 square notches on unit Figure 27 KT1334 attach eyebrow Surround Screws Eyebrow Figure 26 KT1334 KT1335 install surround Insert Hooks KT1335 Figure 27 3 Ins...

Page 23: ...tch into hole in upper right side of the trim Figure 30 3 Reattach wires Figure 30 FP2635 rocker switch On Off Switch Tape wires to back of surround with foil tape Figure 30 Install On Off Switch NOTI...

Page 24: ...d y toucher Ne laisser jamais les enfants toucher le panneau vitr A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed Une...

Page 25: ...service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part of it has been under water Immediately call a qualified service technician to ins...

Page 26: ...ay lit repeat steps 1 and 2 LIGHTING PILOT Pilot Position Check for gas leaks in each of the following locations Pipe from the gas supply line connection to the gas valve Burner connections Field made...

Page 27: ...ER Depress and turn the knob counterclockwise to the ON position It will take less than four 4 seconds for the burner to ignite PILOT POSITION Depress and turn knob to pilot position to keep burner of...

Page 28: ...at sea level The burner on Natural Gas models may be adjusted for high altitude as follows To increase air mixture open the shutter more This will reduce soot formation Figure 32 To decrease air mixt...

Page 29: ...ght film on the glass This is a temporary problem You should clean the glass after the first two weeks of use After that you should clean the glass no more than two or three times a season Use a mild...

Page 30: ...efore cleaning Logs reach high temperatures Make sure clearances to combustibles leave enough room for maintenance and service Carefully reassemble and reseal insert properly after any cleaning or ser...

Page 31: ...is found heater must be adjusted Contact dealer where you bought heater 4 Clean burner and burner ports Figure 37 5 Replace log set and rock wool per instructions on Pages 20 21 Replace glass Make sur...

Page 32: ...it 1 Defective thermocouple Loose thermocouple 1 Check for proper connection of thermocouple to rear of valve 2 Air in gas line 2 Bleed line Contact dealer 3 No gas 3 Check shutoff valve and gas suppl...

Page 33: ...6 blower wiring diagram Blower Snap Disc Variable Speed Control Hi Temp Hi Temp OFF ON 1 2 110 115 V AC Blower Plug Black White Green Blower Motor FP1946 NOTE Unplug power cord before servicing NOTE B...

Page 34: ...34 20306756 380IDV Fireplace Insert REPLACEMENT PARTS 1 2 3 4 6 5 7 8 9 10 11 12 13 14 15 16 17 18 19 20 27 21 22 23 24 25 26 570016 IDV parts FIREBOX COMPONENTS...

Page 35: ...1 57D0007 57D0007 18 Nipple 3 8 x 1 50 1 P1012 P1012 19 Disk Bracket 1 26D3320 26D3320 20 Rear Log 1 1 57D0170 57D0170 21 Left Log 2 1 57D0171 57D0171 22 Right Log 3 1 57D0172 57D0172 23 Left Center L...

Page 36: ...comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed MASSACHUSETTS RESIDENTS ONLY 2 A...

Page 37: ...Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage b...

Page 38: ...38 20306756 380IDV Fireplace Insert This page intentionally left blank...

Page 39: ...20306756 380IDV Fireplace Insert 39 This page intentionally left blank...

Page 40: ...erchez dans la brochure les caract ristique de rendement nerg tique de foyer au gaz nerguide Selon CSA P 4 1 09 149 Cleveland Drive Paris Kentucky 40361 www vermontcastingsgroup com EFFICIENCY RATINGS...

Reviews: