31
20306755
30ILDV Series Gas Fireplace Insert
CLEANING AND MAINTENANCE
YEARLY SERVICE PROCEDURE
Failure to inspect and maintain heater may lead to im-
proper combustion and a potentially dangerous situation.
A qualified technician should do the following once a year.
1. Check pilot flame. Flame should touch approximately
3/8" of the top of thermopile and touch top of thermo-
couple.
Figure 34
If not, contact dealer for service.
2. Turn gas control knob to “OFF” position to shut off gas to
heater.
See step “To Turn Off Gas”, Page 24.
Let heater
cool for 15 minutes. Remove faceplate (see instructions
included with face plate) and glass.
Page 18.
3. Carefully remove log set. If logs are severely deteri-
orated, replace logs. Check logs for sooting. A small
amount of soot along bottom of logs is normal. If exces-
sive sooting is found, heater must be adjusted. Contact
dealer where you bought heater.
FP1943
pilot flame
Thermocouple
Thermopile
FP1943
Figure 34 -
Before taking unit apart, check pilot
flame. Flame should touch thermo-
couple and thermopile
FP1944
check burner ports
9/08
Check Burner Ports
FP1944
Figure 35 -
Check Burner Ports and Burners
4. Clean burner and burner ports.
Figure 35
5. Replace log set and rock wool per instructions on Pages
19-21. Replace glass. Make sure gasket along perimeter
of glass contacts face of firebox and forms an airtight
seal. Realign if airtight seal is not formed. Replace glass
and glass frame if damaged.
6. Inspect area behind face plate. Clean if necessary.
Check gas control valve and all gas lines. If damaged,
do not use heater. Contact your dealer.
7. Start pilot and turn on main burner. Flames should be
orange/yellow and not touch top of firebox. If pilot or
main burners do not burn correctly, contact your dealer
for service. Monitor blower operation.