40-16 Preparation
D20x22 Series II Navigator HDD
Remote Lockout System - Test
Test Remote Lockout system at least once daily and at the start of every bore. Machine operator must be seated
for machine to be in Drill mode.
The Remote Lockout system is not operational when machine is in Transport mode.
Complete the following steps with transmitter located near the machine.
Step 1:
Start engine and turn on remote transmitter.
Step 2:
Press
Lockout Button
on remote transmitter. The red light must come on, and buzzer must sound 9
beeps to indicate that the machine is locked out.
Step 3:
Machine operator must attempt to begin drilling. Drilling functions should remain stopped (locked out).
Step 4:
Press
Run Button
and hold for 2 seconds.
Green light comes on, and buzzer sounds for 2 seconds.
Operator will be able to resume drilling.
If test is not successful, ensure transmitter is within range and that machine is running and is in Drill mode
(operator seated at controls). If a problem still exists, contact your Vermeer dealer to determine source, and use
the “Lockout Procedure - Without Remote Lockout System” until the Remote Lockout system is repaired. Refer
to