D20x22 Series II Navigator HDD
Overview 30-61
The last set point is stored and becomes the set point when AutoDrill is resumed. (Refer to “AutoDrill - Resume,”
) If the drilling conditions change since the AutoDrill was paused, then new set points corresponding
to the new drilling conditions can be set by repeating Steps 1–4 in “AutoDrill - Enable (Normal Drilling).” Refer
to
AutoDrill set points are stored until the engine is shut off. When the engine is started, the initial AutoDrill set
points are zero.
If the R.A.T.T. mode has been activated, then the display
(3)
will show the current degree setting.
M
EMORY
S
ETTINGS
FOR
T
HRUST
/R
OTATION
P
RESSURE
Default thrust/rotation pressure settings for various drill modes can be adjusted.
The settings are displayed on the controller, and are saved to permanent memory.
To adjust, place the machine in the preferred drill mode and use the
Speed/Pressure
Trim Switch
(1)
to increase or decrease in increments of 10 psi.
1