45-4 500 Service Hours
BC1000XL Brush Chipper Maintenance
Hydraulic Fluid Strainer - Inspect
Inspect and service strainer after draining the tank when you change the
hydraulic fluid.
Step 1:
Remove fitting (1). Turn strainer (2) counterclockwise and remove it
from the tank.
Step 2:
Clean strainer with a petroleum base paint thinner or other good
cleaning solvent. Scrub strainer with a small soft-bristled brush. Look
for lacquers which may have formed as a result of hot spots in the
hydraulic system.
Step 3:
Rinse strainer with clean solvent or thinner. Use compressed air to blow
it clean.
Step 4:
Use a suitable thread sealant such as Loctite Vibra-Seal on fitting and
strainer.
Step 5:
Install and tighten strainer and fitting.
WARNING: Eye injury possible. Wear a face shield
when using compressed air to clean or dry solvent-coated
parts.