storage shelf has initialized turn on the other storage shelves one by one and
let them initialize.
■
Turn on the appliance.
■
Ensure that the devices operate properly and begin the configuration for the
device.
Environmental specifications
Table 3-1 lists the requirements for the NetBackup appliance and storage devices.
Table 3-1
Environmental requirements
Requirement
Component
100VAC (U.S.)
Storage shelf nominal voltage
10°C to 35°C (50°F to 95°F)
Operating temperature
-10°C to 50°C (14°F to 122°F)
Storage temperature
-40°C to 60°C (-40°F to 140°F)
Transportation temperature
10% to 80%
Relative humidity operating range
10% to 90%
Relative humidity storage range
5% to 90%
Relative humidity transportation range
10°C (50°F) per hour maximum
Relative humidity operating gradient
15°C (59°F) per hour maximum
Relative humidity storage gradient
-30 meters to 3,000 meters (-98.4 FT to 9842.5
FT)
In altitudes from -60 meters to +1,800 meters,
the ambient temperature ranges from 5°C to
35°C.
When the altitude ranges from 1,800 meters to
3,000 meters, the environment temperature
decreases by 0.6°C if the altitude increases by
100 meters.
Operating altitude
-30 meters to 3,000 meters
Storage altitude
25
Preparing for hardware installation
Environmental specifications