2.4
GAS TIGHTNESS AND INLET PRESSURE (SLIDE CONTROL
MODELS).
a)
Remove the pressure test point screw from the pressure test point and
fit a manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress the control lever to the position marked pilot. Hold down the
control lever for a few seconds to purge the pipe work. The burner
should light, continue to hold the control lever for a few seconds to latch
the valve then lift to the full-on position.
d)
Check that the gas pressure for Natural Gas (G20) models is
20.0 mbar
(+/- 1.0mbar) 8.0 in w.g.(+/- 0.4 in w.g.)
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
2.5
GAS TIGHTNESS AND INLET PRESSURE (REMOTE CONTROL
MODELS).
a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and carry out a gas tightness test.
c)
Depress both the round buttons on the handset. The fire will then
commence its ignition sequence and will light to high. See page 29
for full details of the operating method for the fire.
d)
Check that the gas pressure is
20.0 mbar (+/- 1.0mbar) 8.0 in w.g.(+/-
0.4 in w.g.)
e)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
19