Fig. 15
m)
Evenly tighten the tensioning nuts to tension both cables and pull the
fire snugly against the wall. Do not overtighten, it is only necessary to
pull the seal up against the sealing face of the wall, it does not need to
be compressed. Check that there are no gaps behind the seal.
n)
With the fire securely in place, if a concealed gas connection has been
made through either of the access holes in the sides of the fire, the
holes should be closed around the pipe to prevent leakage of air
through the gap around the pipe.
o)
Refit the burner. Fit the four retaining screws on manual and slide
control models or two screws on Remote control models and check that
the burner is correctly locked into position. On slide control models refit
the control cable To do this, firstly locate the nipple on one end of the
cable into recess in operating arm and then secure the front part of the
operating arm back onto the rear of the operating arm with the retained
screw.
This should not be overtightened. Move the control lever fully
downwards and check that the left hand micro-switch operates the
igniter and that the control valve spindle is fully depressed. Move the
control lever upwards to the “off” position and check that the right hand
(cut-off) micro-switch operates. Check that the control lever operates
smoothly and safely.
NOTE : The cable is factory set, and therefore should need no adjustment
p)
Refit the front burner heat shield to the sides of the fire box (2 Screws)
and secure the trim to the fire using the magnets provided.
17