L
OGGING
O
PTIONS
OS Logging Support
66
E
355/
E
265 U
SER
AND
B
EST
P
RACTICES
G
UIDE
•
Set
*DEBUG=1
or
4
in Edit parameters menu and restart e355 unit.
Figure 38
Debug Port and COM1 Port
*LOG (File Based) •
Log data will be written to a circular buffer, which is stored in file in flash
memory.
•
*LOG
specifies the size in kb, the allowable range is between 50 and 32 x
1024 kb.
•
Log data will include an OS timestamp. When examining timing related issues,
this is much more informative than a time stamp generated on a PC receiving
a log.
•
To upload the logs, Press Bac 4 key simultaneously on VTM menu 1,
or password prompt screen. The log will be uploaded to the device specified
by
*LOGP
, values 1 and U are supported (1 for COM1 port and U for USB
device port).
•
Incremental logs can be obtained by going to the password prompt screen,
uploading the log, and then cancelling VTM password entry prompt. This
upload technique avoids a system restart (entering into VTM menu 1 causes a
system restart).
•
Hardware interrupts are disabled during the writing of log in circular buffer,
overhead of
*LOG
is much less compared to the overhead of
*DEBUG
.
•
Control command G31 with parameter 01O (character 'O' at the end) enables
the
*LOG
logging with size set to 1024 (1MB) and
*LOGP
value to 1.
•
Control command G32 with parameter O retrieves the log one record at a time
until the log is empty.
U
A
R
T
U
S
B
R
TS
(R
S
2
3
2
)
M
IC
R
O
U
S
B
Debug Port
COM1 Port
NOTE
It is recommended to disable
*DEBUG
or
*LOG
system configuration variables
after completion of problem trouble shooting or evaluating the software.
Summary of Contents for e265
Page 1: ...Verifone Part Number DOC087 080 EN A Revision A e355 e265 User and Best Practices Guide...
Page 6: ...CONTENTS 6 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 10: ...PREFACE Conventions and Acronyms 10 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 64: ...SYSTEM MODE VTM Software Versions 64 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 70: ...LOGGING OPTIONS logdump 70 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 74: ...SOFTWARE PACKAGE Downloading 74 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 76: ...CONTROL AND BARCODE APPLICATIONS Pipe Interface 76 E355 E265 USER AND BEST PRACTICES GUIDE...