A
RCHITECTURE
iap_get_keypad_state()
E
355/
E
265 U
SER
AND
B
EST
P
RACTICES
G
UIDE
27
Table 10
presents the PMR-MUX2 status strings.
Table 11
lists the PMR-MUX2 error codes.
Table 10
PMR-MUX2 Status Strings
Message Status String
Name
Description
<0xFF><0x5A>a<num><crc>
ACK Indication
This Message Status is a method for either end of the
link to send and ACK status to the other end. This
indicates that the previous message was received
properly. The
<num>
parameter is an ASCII number
from 2 to 6 to specify the channel number. The <crc>
field is a 16 bit CRC of the complete message including
the 2 byte header and the data field.
<0xFF><0x5A>n<num><code><crc>
NAK indication
This Message Status is a method for either end of the
link to send NAK error codes to the other end in the
event of a message error. The error codes are a single
byte ASCII values. The specific error codes are
described below. The
<num>
parameter is an ASCII
number from 2 to 6 to specify the channel number. The
<crc>
field is a 16 bit CRC of the complete message
including the 2 byte header and the data field.
Table 11
PMR-MUX2 Error Codes
Error
Code
Code Name
Description
0x31
Channel not open
The OS sends this error when the smart device application attempts to write
to a mux channel that it has not opened.
0x32
Invalid Channel Number
The OS sends this error when the smart device app specifies a bad channel
number in an open or close command.
0x33
No Channel is selected
The OS sends this error when a command doesn't contain a channel number.
0x34
Unknown Command
The OS sends this error when a command byte is received that it does not
recognize.
0x35
Channel Already Open
The OS sends this error when the smart device application tries to open a
channel that is already open.
0x36
Channel Already Closed
The OS sends this error when the smart device application tries to close a
channel that is already closed.
0x37
Application Not Open
The OS sends this error when the smart device application tries to open or
write to a channel in which the Verix application has not opened the channel.
Summary of Contents for e265
Page 1: ...Verifone Part Number DOC087 080 EN A Revision A e355 e265 User and Best Practices Guide...
Page 6: ...CONTENTS 6 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 10: ...PREFACE Conventions and Acronyms 10 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 64: ...SYSTEM MODE VTM Software Versions 64 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 70: ...LOGGING OPTIONS logdump 70 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 74: ...SOFTWARE PACKAGE Downloading 74 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 76: ...CONTROL AND BARCODE APPLICATIONS Pipe Interface 76 E355 E265 USER AND BEST PRACTICES GUIDE...