S
YSTEM
M
ODE
- VTM
System Error Log
58
E
355/
E
265 U
SER
AND
B
EST
P
RACTICES
G
UIDE
System Error
Log
The error log screens display internal diagnostic information about the most
recent unrecoverable software error. The following information may need to be
provided when reporting a unit problem.
Figure 30
Error Log
This screen displays the following:
•
TYPE (error type), where the error type code is:
•
1= Data abort: attempt to access data at an invalid address.
•
2= Program abort: attempt to execute code at an invalid address.
•
3= Undefined abort: attempt to execute an illegal instruction.
•
TASK (task number), indicates type of task that was currently executed:
•
1= Verix Terminal Manager.
•
2= First User Task.
•
TIME (time of crash), clock time of the error in the format
YYMMDDhhmmss
,
where YY = year, MM = month, DD = day, hh = hour, mm = minute, and ss =
second.
•
CPSR (Current Program Status Register): contains the processor and state
condition code.
•
PC (Program Counter): holds the execution address.
•
LR (Link Register): holds the return address of the function call.
•
ADDR (fault address): contains the illegal address that the application was
trying to access.
VERIX ERROR LOG
Type 0 OS QTE50301
Task 15 GID 46
Time 160605180642
CPSR 20000010
PC 70009348
LR 7018D8C5
Addr 70105000
NOTE
LR may not always contain the current return address.
Summary of Contents for e265
Page 1: ...Verifone Part Number DOC087 080 EN A Revision A e355 e265 User and Best Practices Guide...
Page 6: ...CONTENTS 6 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 10: ...PREFACE Conventions and Acronyms 10 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 64: ...SYSTEM MODE VTM Software Versions 64 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 70: ...LOGGING OPTIONS logdump 70 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 74: ...SOFTWARE PACKAGE Downloading 74 E355 E265 USER AND BEST PRACTICES GUIDE...
Page 76: ...CONTROL AND BARCODE APPLICATIONS Pipe Interface 76 E355 E265 USER AND BEST PRACTICES GUIDE...