6.9
Element Fitting and Replacement
See section 6.2 - wearing a face mask is required.
Replacements: see section 5.6. If at any time the power limit has been increased, reset
it to its original value (see section 9.0 at the back of this manual for the original value).
New elements must not be mixed with aged elements. If a single heating element fails
within an element circuit containing aged elements, then all heating elements on that
circuit should be replaced. It may not be necessary to replace all heating elements
within a furnace, however the configuration of elements varies between products. If
required, please contact Carbolite Gero Service for advice.
Please provide the serial number of the furnace with all enquiries.
Disconnect the product from the electrical supply.
Part
Quantity
Elements
6
Centre braids
3
End braids
(attached to the terminal blocks)
6
Nuts
12
Bolts
12
Washers
24
Tools required:
l
1 x screwdriver cross-head
l
2 x 10 mm spanner
Remove the top cover to gain access to the element connections.
24