17
www.ventilation-system.com
DESCRIPTION OF MOBILE APPLICATION CONTROL BUTTONS
ON/Standby. The
Standby
mode depends on the position of the DIP
switch No. 2 (see section
Setting the ventilator operation mode
using DIP switches
)
Selection of the preset speed: Speed I, II and III respectively.
Manual speed setup. To activate the scroll bar, check it.
Ventilation
The ventilator operates in the supply or extraction mode at a set speed.
The fan rotation direction depends on the position of the DIP switch 3.
Regeneration mode
The rotation direction of both fans changes to opposite every 70
seconds. Heat recovery is performed in this mode.
Air supply mode
The ventilation unit operates exclusively in air supply mode.
Night mode.
Activation of Speed I timer without changing the ventilator operation
mode (8 hours by default, adjustable in the
Settings – Timers
menu).
Weekly schedule.
Activation of the ventilator week-scheduled operation.
Party mode.
Activation of the Speed III timer without changing the ventilator
operation mode (4 hours by default, adjustable in the
Settings – Timers
menu).
DESCRIPTION OF MOBILE APPLICATION INDICATORS
Current type of connection to the ventilator.
Home connection or connection via a cloud server through Internet respectively.
Speed III activation indicator. It goes on after activation of any sensor.
When this mode is activated, all the other modes are deactivated. Upon elapse of the turn-off delay timer countdown
(30 minutes by default) the ventilation unit reverts to the previous mode. Press
Power
to deactivate this operation
mode.
Humidity indicator. It glows if the indoor humidity is above the set point.
Indicator of external relay sensor. It glows if the external relay sensor is activated.
Indicator of the external analogue sensor 0-10 V. It indicates exceeding the setpoint on the external sensor.
Alarm indicator. It glows in emergency case and can be of two colours:
red
– lights up in case of emergency shutdown of the ventilator
orange
– lights up in case if there is no battery or the battery is low
Filter replacement indicator. To reset the filter timer, go to
Menu->Settings->Filter
.
When simultaneously activating several operation modes that exclude each other, the ventilator selects the mode according to the
following priority:
1. Night mode timer or Party mode timer.
2. Standby.
3. Boost mode.
4. Weekly Schedule.
5. Regular mode.
Summary of Contents for TwinFresh Style Wi-Fi
Page 30: ...30 TwinFresh Style Wi Fi www ventilation system com...
Page 32: ...V222 1EN 01...