background image

www.ventilation-system.com

9

 

VENTILATOR MOUNTING

READ THE USER’S MANUAL PRIOR TO MOUNTING  

THE VENTILATOR. 

ATTENTION! 

DO NOT BLOCK THE AIR DUCT OF THE INSTALLED VENTILATOR WITH  DUST 

ACCUMULATING MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC. AS IT 

PREVENTS AIR CIRCULATION IN THE ROOM. 

1. Prepare round core holes in the outer wall. 

Prepare one or two round core holes in the outer wall, depending on the ventilation system equipment.

For efficient operation of the ventilation system it is recommended to install the ventilators as far apart from one another as possible.  

While preparing a core hole make preparations for layout of the power cable and other required cables. 

The core hole size and minimum distance to a mounting surface, for example, a wall, ceiling or a window as well as the minimum 

distance between the ventilators are shown below. 

min 1 m

min 39 3/8"

min 1 m

min 39 3/8"

min 

1 m

min 

39 3/8"

min 500 mm

min 19  11/16"

Ø 180 mm

Ø 7  1/16"

min 500 mm

min 19  11/16"

min 500 mm

min 19  11/16"

2. Prepare air ducts of required length. 

A

B

L

Measure the wall thickness B. 

The air duct length is calculated as L = B + A, where A means an air duct 

segment that protrudes in the outer wall to enable installation of the 

external grille of the outer ventilation hood. For details, see  the table 

below. 

Outer hood/ external grille model 

A, mm 

EH 160

10

MVM 152 bVsN

0

EH-2 160

10–100

MV 150 bVs

0

MVM 150 bV N

Cut the air duct to the length L, without consideration to the cable 

recess.  

Insert the air duct into a prepared hole in the wall. 

The cable recesses must be located on inner wall side. 

The air duct end on the must be flush with the inner wall side. 

 

V127EN-01.indd   9

29.03.2016   9:56:06

Summary of Contents for TwinFresh Easy RL-50-7

Page 1: ...USER S MANUAL Single room reversible energy regeneration ventilator TwinFresh Easy V127EN 01 indd 1 29 03 2016 9 56 03...

Page 2: ...cal specification applies to the installation and mounting of the single room energy regeneration reversible ventilator TwinFresh Easy hereinafter the unit as mentioned in the Safety Requirements and...

Page 3: ...the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or e...

Page 4: ...Internal square ventilation grille 1 item 2 items External grille 1 item 2 items Control panel 1 item 1 item Remote control 1 item 1 item Mounting fasteners 1 item 1 item Mounting box 1 item 1 item U...

Page 5: ...0 18 50 29 Filters G3 MERV 7 F8 MERV 13 option Transported air temperature C F from 30 22 to 50 122 Noise level 1 m dB A Sones 24 0 6 31 1 0 34 1 2 24 0 6 31 1 0 34 1 2 Noise level 3 m dB A Sones 15 0...

Page 6: ...r ow DESIGN AND OPERATING LOGIC The ventilator consists of decorative protecting internal grille a cartridge an air duct with a sound absorbing material and a protecting external ventilation grille Ca...

Page 7: ...up to 97 heat energy In 70 seconds as the ceramic regenerator gets warmed the ventilator is switched to supply mode Cycle II Fresh intake air from outside flows through the ceramic regenerator and ab...

Page 8: ...the wires to the installation place Insert the supplied mounting box for flush wall mounting 2 Use a screwdriver to carefully undo the clips on the backside of the control panel and disconnect the fro...

Page 9: ...example a wall ceiling or a window as well as the minimum distance between the ventilators are shown below min 1 m min 39 3 8 min 1 m min 39 3 8 min 1 m min 39 3 8 min 500 mm min 19 11 16 180 mm 7 1...

Page 10: ...ct No glue is required for fixation 1 Ventilator with outer hood option Mark the sound absorbing layer at the end of the air duct as 1 Cut the excessive part of the sound absorbing layer Insert the ad...

Page 11: ...The circuit breaker trip current must exceed the consumption current of the ventilator For details please refer to table at page 5 For electric installations use insulated durable and heat resistant e...

Page 12: ...re In case of power cut off the set parameters are saved in the non volatile memory of the control panel VENTILATOR OPERATION WITH THE BUTTONS ON THE LCD CONTROL PANEL Turning ventilator on off Enteri...

Page 13: ...press the button sequentially Operation hour meter Package Turning OFF mode Speed setting 5 Speed setting in Engineering menu Operation hour meter The hour meter shows the actual hours run time To res...

Page 14: ...ion Ventilation mode The ventilator operates in air extract or air supply mode Regeneration mode In this mode the ventilator switches between supply and extract mode each 70 seconds with heat regenera...

Page 15: ...UCT CLOSING Close Open Round internal grille To close the air duct rotate a small handle between the louvre shutters clockwise against stop To open the air duct rotate this handle counter clockwise V1...

Page 16: ...rs as often as required but at least 3 times a year After expiry of the period set for the hour meter factory setting 90 days the filter replacement indicator appears on the control panel display Wash...

Page 17: ...he ventilator off Contact the Seller for further information Low air flow Low set fan speed Set higher speed The filters the fan or the regenerator is soiled Clean or replace the filter Clean the fan...

Page 18: ...f the unit model and the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the un...

Page 19: ...Seller s Stamp Seller s Stamp Installation Company Stamp This is to certify acceptance of the complete ventilator delivery with the user s manual The warranty terms are acknowledged and accepted Custo...

Page 20: ...V127EN 01 V127EN 01 indd 20 29 03 2016 9 56 11...

Reviews: