Vents TwinFresh Easy RL-50-7 User Manual Download Page 12

www.ventilation-system.com

12

TwinFresh Easy

VENTILATOR OPERATION  

The ventilator is operated with the control panel. 
The following parameters are set with the control panel:   

•  Ventilator speed stage: I, II, III;

•  Operation mode: Regeneration or Ventilation;

•  Timer-based operation of the ventilator: 4 hours at speed III or 8 hours at speed I. 

The control panel displays the following parameters: 

•  current ventilator speed;

•  current operation mode of the ventilator;

•  timer operation status (On/Off);

•  filter replacement/cleaning need according to indications of the hour meter (factory setting 90 days);

•  emergency shutdown of the ventilator in case of a motor failure.   

In case of power cut-off the set parameters are saved in the non-volatile memory of the control panel.  

VENTILATOR OPERATION WITH THE BUTTONS ON THE LCD CONTROL PANEL 

Turning ventilator 

on/off 

Entering engineering menu

Setting selecting

Changeover 

to next menu item 

Exiting setup menu

Entering setup menu 

1. Turning ventilator on/off   

Connect the ventilator to power mains. The control panel displays the operating status of 
the timer.    

Press the button 

 to turn the ventilator off.   

The control panel displays the current speed, active operation mode and the timer 
operation status.  

2. User menu. 

Press the button 

  in cycles for changeover between the user menu items.  

 — Speed;  
 — Timer;

 — Operation mode;

 — Engineering menu.  

3. Parameter setting in user menu. 

 — Speed   

Parameter setting using 

 or 

 buttons

.

Speed I —     
Speed II —    
Speed III —  

 

V127EN-01.indd   12

29.03.2016   9:56:08

Summary of Contents for TwinFresh Easy RL-50-7

Page 1: ...USER S MANUAL Single room reversible energy regeneration ventilator TwinFresh Easy V127EN 01 indd 1 29 03 2016 9 56 03...

Page 2: ...cal specification applies to the installation and mounting of the single room energy regeneration reversible ventilator TwinFresh Easy hereinafter the unit as mentioned in the Safety Requirements and...

Page 3: ...the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or e...

Page 4: ...Internal square ventilation grille 1 item 2 items External grille 1 item 2 items Control panel 1 item 1 item Remote control 1 item 1 item Mounting fasteners 1 item 1 item Mounting box 1 item 1 item U...

Page 5: ...0 18 50 29 Filters G3 MERV 7 F8 MERV 13 option Transported air temperature C F from 30 22 to 50 122 Noise level 1 m dB A Sones 24 0 6 31 1 0 34 1 2 24 0 6 31 1 0 34 1 2 Noise level 3 m dB A Sones 15 0...

Page 6: ...r ow DESIGN AND OPERATING LOGIC The ventilator consists of decorative protecting internal grille a cartridge an air duct with a sound absorbing material and a protecting external ventilation grille Ca...

Page 7: ...up to 97 heat energy In 70 seconds as the ceramic regenerator gets warmed the ventilator is switched to supply mode Cycle II Fresh intake air from outside flows through the ceramic regenerator and ab...

Page 8: ...the wires to the installation place Insert the supplied mounting box for flush wall mounting 2 Use a screwdriver to carefully undo the clips on the backside of the control panel and disconnect the fro...

Page 9: ...example a wall ceiling or a window as well as the minimum distance between the ventilators are shown below min 1 m min 39 3 8 min 1 m min 39 3 8 min 1 m min 39 3 8 min 500 mm min 19 11 16 180 mm 7 1...

Page 10: ...ct No glue is required for fixation 1 Ventilator with outer hood option Mark the sound absorbing layer at the end of the air duct as 1 Cut the excessive part of the sound absorbing layer Insert the ad...

Page 11: ...The circuit breaker trip current must exceed the consumption current of the ventilator For details please refer to table at page 5 For electric installations use insulated durable and heat resistant e...

Page 12: ...re In case of power cut off the set parameters are saved in the non volatile memory of the control panel VENTILATOR OPERATION WITH THE BUTTONS ON THE LCD CONTROL PANEL Turning ventilator on off Enteri...

Page 13: ...press the button sequentially Operation hour meter Package Turning OFF mode Speed setting 5 Speed setting in Engineering menu Operation hour meter The hour meter shows the actual hours run time To res...

Page 14: ...ion Ventilation mode The ventilator operates in air extract or air supply mode Regeneration mode In this mode the ventilator switches between supply and extract mode each 70 seconds with heat regenera...

Page 15: ...UCT CLOSING Close Open Round internal grille To close the air duct rotate a small handle between the louvre shutters clockwise against stop To open the air duct rotate this handle counter clockwise V1...

Page 16: ...rs as often as required but at least 3 times a year After expiry of the period set for the hour meter factory setting 90 days the filter replacement indicator appears on the control panel display Wash...

Page 17: ...he ventilator off Contact the Seller for further information Low air flow Low set fan speed Set higher speed The filters the fan or the regenerator is soiled Clean or replace the filter Clean the fan...

Page 18: ...f the unit model and the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the un...

Page 19: ...Seller s Stamp Seller s Stamp Installation Company Stamp This is to certify acceptance of the complete ventilator delivery with the user s manual The warranty terms are acknowledged and accepted Custo...

Page 20: ...V127EN 01 V127EN 01 indd 20 29 03 2016 9 56 11...

Reviews: