Read the user’s manual carefully prior to installing and operating the unit.

Fulfil the user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical and 

technical norms and standards.

The warnings contained in the user’s manual must be considered most seriously since they contain vital personal safety information.

Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage.

After a careful reading of the manual, keep it for the entire service life of the unit.

While transferring the unit control the User’s manual must be turned over to the receiving operator. 

Symbol legend:

WARNING!

DO NOT!

The user’s manual consisting of the technical details, operating 

instructions and technical specification applies to the installation 

and mounting of the single-room energy regeneration reversible 

ventilator  TwinFresh Easy, (hereinafter «the unit» as mentioned 

in the «Safety Requirements» and «Manufacturer’s Warranty» 

sections as well as in warnings and information blocks). 

Safety requirements ................................................................................................ 2
Purpose ...................................................................................................................... 4
Delivery set ................................................................................................................ 4
Designation key ........................................................................................................ 4
Main technical parameters .................................................................................... 5
Design and operating logic .................................................................................... 6
Mounting and set-up .............................................................................................. 8
Unit connection and control ................................................................................. 11
Maintenance ............................................................................................................. 16
Troubleshooting ....................................................................................................... 17
Storage and transportation regulations ............................................................. 17
Manufacturer's warranty ........................................................................................ 18
Acceptance certificate ............................................................................................ 19
Seller information .................................................................................................... 19
Installation certificate .............................................................................................. 19
Warranty card ........................................................................................................... 19

CONTENT

SAFETY REQUIREMENTS 

UNIT MOUNTING AND OPERATION SAFETY PRECAUTIONS

• 

Disconnect the unit from power mains 

prior to any installation operations.

• 

Unpack the unit with care. 

• 

Do not lay the power cable of the unit in 

close proximity to heating equipment.

• 

While installing the unit follow the safety 

regulations specific to the use of electric 

tools.

V127EN-01.indd   2

29.03.2016   9:56:04

Summary of Contents for TwinFresh Easy RL-50-7

Page 1: ...USER S MANUAL Single room reversible energy regeneration ventilator TwinFresh Easy V127EN 01 indd 1 29 03 2016 9 56 03...

Page 2: ...cal specification applies to the installation and mounting of the single room energy regeneration reversible ventilator TwinFresh Easy hereinafter the unit as mentioned in the Safety Requirements and...

Page 3: ...the unit from power mains prior to any technical maintenance Do not store any explosive or highly flammable substances in close proximity to the unit When the unit generates unusual sounds odour or e...

Page 4: ...Internal square ventilation grille 1 item 2 items External grille 1 item 2 items Control panel 1 item 1 item Remote control 1 item 1 item Mounting fasteners 1 item 1 item Mounting box 1 item 1 item U...

Page 5: ...0 18 50 29 Filters G3 MERV 7 F8 MERV 13 option Transported air temperature C F from 30 22 to 50 122 Noise level 1 m dB A Sones 24 0 6 31 1 0 34 1 2 24 0 6 31 1 0 34 1 2 Noise level 3 m dB A Sones 15 0...

Page 6: ...r ow DESIGN AND OPERATING LOGIC The ventilator consists of decorative protecting internal grille a cartridge an air duct with a sound absorbing material and a protecting external ventilation grille Ca...

Page 7: ...up to 97 heat energy In 70 seconds as the ceramic regenerator gets warmed the ventilator is switched to supply mode Cycle II Fresh intake air from outside flows through the ceramic regenerator and ab...

Page 8: ...the wires to the installation place Insert the supplied mounting box for flush wall mounting 2 Use a screwdriver to carefully undo the clips on the backside of the control panel and disconnect the fro...

Page 9: ...example a wall ceiling or a window as well as the minimum distance between the ventilators are shown below min 1 m min 39 3 8 min 1 m min 39 3 8 min 1 m min 39 3 8 min 500 mm min 19 11 16 180 mm 7 1...

Page 10: ...ct No glue is required for fixation 1 Ventilator with outer hood option Mark the sound absorbing layer at the end of the air duct as 1 Cut the excessive part of the sound absorbing layer Insert the ad...

Page 11: ...The circuit breaker trip current must exceed the consumption current of the ventilator For details please refer to table at page 5 For electric installations use insulated durable and heat resistant e...

Page 12: ...re In case of power cut off the set parameters are saved in the non volatile memory of the control panel VENTILATOR OPERATION WITH THE BUTTONS ON THE LCD CONTROL PANEL Turning ventilator on off Enteri...

Page 13: ...press the button sequentially Operation hour meter Package Turning OFF mode Speed setting 5 Speed setting in Engineering menu Operation hour meter The hour meter shows the actual hours run time To res...

Page 14: ...ion Ventilation mode The ventilator operates in air extract or air supply mode Regeneration mode In this mode the ventilator switches between supply and extract mode each 70 seconds with heat regenera...

Page 15: ...UCT CLOSING Close Open Round internal grille To close the air duct rotate a small handle between the louvre shutters clockwise against stop To open the air duct rotate this handle counter clockwise V1...

Page 16: ...rs as often as required but at least 3 times a year After expiry of the period set for the hour meter factory setting 90 days the filter replacement indicator appears on the control panel display Wash...

Page 17: ...he ventilator off Contact the Seller for further information Low air flow Low set fan speed Set higher speed The filters the fan or the regenerator is soiled Clean or replace the filter Clean the fan...

Page 18: ...f the unit model and the brand name with the information stated on the unit packing and in the user s manual User s failure to ensure timely technical maintenance of the unit External damage to the un...

Page 19: ...Seller s Stamp Seller s Stamp Installation Company Stamp This is to certify acceptance of the complete ventilator delivery with the user s manual The warranty terms are acknowledged and accepted Custo...

Page 20: ...V127EN 01 V127EN 01 indd 20 29 03 2016 9 56 11...

Reviews: