VENTEV INNOVATIONS BTRM200 Battery Test Remote Monitoring System – User Guide V1.0
50
The Router is the message destination. The Router looks at the message’s port,
checks its port forwarding table to see if the UDP port 162 is forwarded to a local
LAN IP address. If so, delivers it to that IP address (in this case the Host
Computer), otherwise the message is discarded.
10.3.
Port Table
Function
Default Port Values
TCP/IP
UDP
Web Page Access (http)
80
SNMP Management Access
161
SNMP Notifications
162
21
DNP3
20000
Firmware Update
16384
11. Specifications and Warranty
Electrical Specifications
Operating Voltage
9 to 32 VDC
Battery Max Current
10 A Continuous
Charger Max Current
10 A Continuous
Load 1 & 2 Combined Max Current
10 A Continuous
Battery and Charger
Voltage Measurement
0 to 32V ± 1%
Current Measurement
0 to 10 Amps ± 1%
Environmental
Temperature
-20° C to +60° C
Humidity
5 % to 95% Non Condensing
Mechanical
Size
6.25” H X 2.8” D X 1.2” W
Weight
5.0 oz (142 g)
Mounting
Din rail mounting
Warranty
One Year