7.4.1. IO Channel 1
7.4.1.1.
Analog Input 0-32V
This allows the user to enable an analog input level for triggering alarms
from external sources (door switches, solid state relays, etc.).
7.4.1.2.
Digital Input Alarm if < 1V
This allows the user to enable a digital input logic levels that is less than 1
volt to trigger an alarm from external sources (door switches, solid state
relays, etc.).
7.4.1.3.
Digital Input Alarm if > 2V
This allows the user to enable a digital input logic levels that is greater
than 2 volt to trigger an alarm from external sources (door switches, solid
state relays, etc.).