background image

9

 

4.0   Electrical

 

 

 

 

 

 

 

 

 

 

5.0   Maintenance

 

 

 
5.1 

Cleaning the Unit (Fig.6)

 

 

1. In addition to removing odours, providing fresh 
air and recovering heat, this unit extracts airborne 
impurities such as dust, dirt and grease. These 
gradually build up and detract from the efficiency 
and appearance of the unit.

 

 

2. To ensure optimum performance, the unit 
should be cleaned every 3 to 6 months or at 
periods determined by the level of contamination 
experienced and according to the following 
procedure.

 

 

3. Isolate the mains power supply.

 

 

4. Release the catches on either side of 
the grille surround and remove the two 
filter holders. 

 

 

 

 
 
 
 

 

 

 

 

5. Remove the filter from the filter holders.

 

 

6. Remove the grille surround after unscrewing its 
retaining screws. Slide out the heat exchanger.

 

 

7. Wash the grille, filter and heat exchanger in 
warm water using a mild detergent and dry 
thoroughly.

 

 

CAUTION: 

Keep water away from all electrical 

components and wiring within the unit.

 

 

8. Reassemble in reverse order ensuring the 
filter and heat exchanger are seated correctly.

 

 

9. Switch power supply on and check the 
operation of the unit. 
 

 

  5.2 

Inlet Blank 

 

1. An inlet blanking plate is provided with 
the unit. With this in place the HR200WJ 
acts as an extract only fan. 
 
2. Release the catch for the supply 
side(left side) grille and remove the grille 
 
3. Place the inlet blanking plate between 
the grille and the filter  
 
4. Replace the grilled with the blanking 
plate in place. The unit will now operate as 
an extract only ventilation unit 

 

Spares and Accessories 

Part Number 

Internal grille with grille inserts 

452089 

Filter pack of 4 

452091 

Heat exchanger cube 

452092 

Motor impeller unit spare 

479429 

2.5uF Capacitor spare 

479430 

6uF Capacitor spare 

479431 

2uF Capacitor spare 

479432 

1uF Capacitor spare 

479433 

External bezel spare (Grey) 

479434 

External cowl spare (Grey) 

479435 

Extension sleeve (Brown) 

457340 

Fig. 6 

Inlet blanking plate 

Summary of Contents for HR200WJ

Page 1: ...WJ Through the wall Heat Recovery Ventilator Installation and Maintenance Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE SAVE THESE INSTRUCTIONS Stock Ref No HR200WJ 47...

Page 2: ...should be provided with a local isolator switch fitted with a 3A fuse capable of disconnecting all poles and having a contact separation of at least 3mm 5 These units must be earthed 6 Precautions mu...

Page 3: ...and maintenance 3 Certain applications may require the installation of sound attenuation to achieve the sound levels required 4 The unit must not be connected directly to a tumble drier 5 The supply...

Page 4: ...racts air while transferring heat from the stale exhaust airflow to the fresh intake airflow This provides up to 75 heat recovery from the stale extracted air 3 The power consumption for the unit is 9...

Page 5: ...Do not site the appliance in the vicinity of excessive levels of airborne oil or grease 7 If the unit is installed in a room containing a fuel burning appliance the installer must ensure that air rep...

Page 6: ...the cable runs WARNING Before deciding on the final position for the unit check there are no buried cables pipes or obstructions on the outside wall Cable requirements Suitably Basec or Har approved f...

Page 7: ...the top right hand side of the housing Note for the purpose of condensation drainage a prop is fitted to the underside of the housing to cause it to adopt a downwards tilt to the outside wall 4 Fix th...

Page 8: ...Connect the conductors of the cable to the appropriate terminals in accordance with the wiring diagram Fig 5 NOTE Refer to the fitting and wiring instructions provided with the controller used The wi...

Page 9: ...thoroughly CAUTION Keep water away from all electrical components and wiring within the unit 8 Reassemble in reverse order ensuring the filter and heat exchanger are seated correctly 9 Switch power s...

Page 10: ...4 months Clean cell replace filters the new filters will be supplied with 4 additional Timestrip indicators Note The above is the minimum requirement more frequent cleaning intervals may be needed dep...

Page 11: ...mand Control Declared Max Internal External Leakage Rates for BVUs or carry over for regenerative heat exchangers only Ext Leakage Rates for Ducted UVUs 5 Internal 5 External Mixing Rate of Non Ducted...

Page 12: ...to misuse neglect or damage Has not been modified or repaired by any person not authorised by the company IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product carriage paid to your...

Reviews: