4
Plan where and how the ductwork will be
installed.
A straight, short duct run will allow the hood to
perform most efficiently.
Install proper-sized ductwork, elbows and roof
cap. Connect metal ductwork to cap and work
back towards the hood location. Use 2” metal foil
duct tape to seal the joints.
Run 3-wire power supply cable to installation
location.
We recommend to install the hood at a
minimum distance of 30” above cooking
surface. A maximum of 36” above cooktop
is highly recommended for best capture of
cooking impurities.
Distances over 36” are at the installer and users
discretion.
10-ft. ceilings require 10-ft flue extension, part
no. 19325 (sold separately).
1. INSTALL
DUCTWORK
8"
R
OUND
D
UCT
R
OOF
C
AP
H
OOD
HH0153A
D
ECORATIVE
F
LUE
8"
ROUND
ADAPTER
/
DAMPER
30"
TO
36"
ABOVE
COOKING
SURFACE
HH0154A
1" M
IN
.
Installation over a gas range:
Refer to gas range manufacturer’s guidelines for
the recommended CFM. If two IK700 Series range
hoods are required, the space between both hoods
should not be less than 1”.