12
7. CONNECT
WIRING
(CONT'D)
HD0434
H
OUSE
WIRING
3. Run house wiring through wire clamp and into
blower box electrical box. Tighten wire clamp to
secure house wiring cable to blower box.
4. Measure the required length of 8" round metal duct
from the adapter/damper to the ductwork rough-in
in the ceiling. Connect this section of duct to the
adapter/damper, then connect to ceiling duct and
seal both joints with metal foil duct tape.
HE0126
5. Connect hood power cable to house wiring using
provided wire connectors: BLACK to BLACK, WHITE
to WHITE and GREEN or BARE wire to GREEN
ground screw.
DO NOT FORGET TO CONNECT
THE GROUND.
6.
Reinstall electrical box cover using both screws
previously removed.