DESCRIPTION 

L  models  description:  self-powered  12  Vdc  sounder  with  high-brightness  low-consumption  LED  flashing  unit  -  double  reed 
tamper against sounder opening and against any attempts of removing the sounder from the wall – programmable sounds and 
timings  –  alarm  counting  –  optical  and  acoustic  signaling  of  System  ON/OFF  (arming/disarming)  -  electronic  circuit  protected 
against  polarity  inversion  and  tropicalized  by  resin  immersion  –  microprocessor  self-check  of  recharge,  battery  and  speaker  – 
flash reset input – internal cover made of 10/10 zinc-plated steel (Aluzinc system) – outside cover made of painted ABS or 10/10 
zinc-plated steel (Aluzinc system) or shiny stainless steel according to the model chosen.   

LS models description: technical features as per L models, with patented double micro anti-foam anti-shock device against hard 
hits (patent no. 00238576). 

Summary of Contents for RIALTO L

Page 1: ...timings alarm counting optical and acoustic signaling of System ON OFF arming disarming electronic circuit protected against polarity inversion and tropicalized by resin immersion microprocessor self...

Page 2: ...TERMINAL NEGATIVE INPUT FOR SOUND BLOCK It activates the sound interruption trigger by taking a negative 0V to terminal no 4 D STI TERMINAL SYSTEM STATUS NOTICE PERMANENT MOMENTARY ALARM SYSTEM ON OFF...

Page 3: ...5 STI to 12V for 10 seconds then take away the voltage from the terminal These steps launch the test which will last 60 seconds During the test the sounder verifies its own functioning and notifies an...

Page 4: ...ive missing alarm if disconnected or 0V ON Negative missing alarm if disconnected or 12V Chart 6 TONE SELECTION DIP 4 TONE FREQUENCY LIMITS Hz OFF default setting CERTIFIED Increasing Continuous Decre...

Page 5: ...nd the power supply to the control panel 5 Close both internal and external covers using the screws provided 6 Battery must have UL94 HB flammability rate 7 Power supply must be of SELV type Attention...

Page 6: ...5 mA Vc 12V 0 3 mA Vc 0V Open collector 10mA max LED flashing unit life 1 000 000 flashes Timing 3 minutes settable at 8 minutes Battery capacity 12V 2 0 Ah Switch tamper range N C 0 2 A max Fundament...

Page 7: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 7 of 8 NOTE...

Page 8: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 8 of 8 Via del Lavoro 10 30030 Salzano VE Tel 39 041 5740374 Fax 39 041 5740388 Web site www venitem com E mail info venitem com...