CONNECTION SCHEME 

 
 
A) CONNECTION USING THREE WIRES.

 

Connect 13.8 Volt power supply coming from the control panel to the corresponding terminals: 
-RIC negative; +RIC positive; +C positive-missing trigger. 
NOTE: DIP-SWITCH no. 2 is set by the manufacturer in OFF position, POSITIVE-MISSING TRIGGER. 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

B) CONNECTION USING TWO WIRES 

Connect 13.8 Volt power supply coming from the control panel to the corresponding terminals: 
-RIC negative; +RIC positive. (make a jumper bC and +RIC). 
NOTE: DIP-SWITCH no.2 is set by the manufacturer in OFF position, POSITIVE-MISSING TRIGGER 

 

 

 

 

 

 

 

 

 

 

 

 

 

C) BLS TERMINAL, NEGATIVE INPUT FOR SOUND BLOCK 
    It activates the sound interruption trigger by taking a negative (0V) to terminal no. 4.   
 
D) STI TERMINAL, SYSTEM STATUS NOTICE (PERMANENT/MOMENTARY ALARM SYSTEM ON/OFF) 

DIP 3 in OFF position 

 

Giving a positive to terminal no. 5, all LEDs of the flashing unit flash 3 times (ON). Anomalies are reset to zero. 

 

Taking away the positive, all LEDs stay lighted up steady for 5 seconds (OFF) and the complete sounder test is launched. In 
case of anomalies, they are duly notified.  

 
PONT 1 (R74)
 – UNTOUCHED (STANDARD SETTING): 

Momentary ON-OFF signaling and 1 LED keeps on flashing in intermittent mode 

until there is positive signal to terminal no. 5

PONT 1 (R74) – CUT: 

Momentary ON-OFF signaling

  

GND 0V

 

+13.8Vdc and SOUNDER TRIGGER

 

TAMPER LINE

 

CONTROL PANEL

 

GND 0V

 

+13.8V

 

OUTDOOR SOUNDER TRIGGER

 

TAMPER LINE

 

CONTROL PANEL

 

Summary of Contents for RIALTO L

Page 1: ...timings alarm counting optical and acoustic signaling of System ON OFF arming disarming electronic circuit protected against polarity inversion and tropicalized by resin immersion microprocessor self...

Page 2: ...TERMINAL NEGATIVE INPUT FOR SOUND BLOCK It activates the sound interruption trigger by taking a negative 0V to terminal no 4 D STI TERMINAL SYSTEM STATUS NOTICE PERMANENT MOMENTARY ALARM SYSTEM ON OFF...

Page 3: ...5 STI to 12V for 10 seconds then take away the voltage from the terminal These steps launch the test which will last 60 seconds During the test the sounder verifies its own functioning and notifies an...

Page 4: ...ive missing alarm if disconnected or 0V ON Negative missing alarm if disconnected or 12V Chart 6 TONE SELECTION DIP 4 TONE FREQUENCY LIMITS Hz OFF default setting CERTIFIED Increasing Continuous Decre...

Page 5: ...nd the power supply to the control panel 5 Close both internal and external covers using the screws provided 6 Battery must have UL94 HB flammability rate 7 Power supply must be of SELV type Attention...

Page 6: ...5 mA Vc 12V 0 3 mA Vc 0V Open collector 10mA max LED flashing unit life 1 000 000 flashes Timing 3 minutes settable at 8 minutes Battery capacity 12V 2 0 Ah Switch tamper range N C 0 2 A max Fundament...

Page 7: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 7 of 8 NOTE...

Page 8: ...MA SE RTL0 03 01 Manuale Rialto Triade Lido Eng rev1 Page 8 of 8 Via del Lavoro 10 30030 Salzano VE Tel 39 041 5740374 Fax 39 041 5740388 Web site www venitem com E mail info venitem com...

Reviews: